5. Anomalies de fonctionnement
Identifiez votre problème dans la colonne «
CONSTAT
CAUSES
1.
MAUVAISE MÉTHODE D'ALLUMAGE
2.
CHEMINÉE FROIDE
3.
CONDITIONS ATMOSPHÉRIQUES
REFOULEMENT À L'ALLU-
MAGE
4.
LOCAL EN DÉPRESSION
5.
CHICANES MAL RÉGLÉES
6.
OBSTRUCTION DU CONDUIT
VÉRIFIER LES CAUSES: 2 - 3 - 4 - 5 - 6
LE FEU NE
7.
COMBUSTIBLE D'ALLUMAGE INSUFFISANT
DÉMARRE PAS
8.
HUMIDITÉ EXCESSIVE DU COMBUSTIBLE D'ALLU-
MAGE
VÉRIFIER LES CAUSES: 3 - 4 - 5
9.
HUMIDITÉ EXCESSIVE DU COMBUSTIBLE
10.
FAIBLE QUANTITÉ DE COMBUSTIBLE
LE FEU EST
DORMANT
11.
MAUVAISE QUALITÉ DU COMBUSTIBLE
12.
DYSFONCTIONNEMENT DE LA BOITE À AIR
13.
PRISE D'AIR INSUFFISANTE
VÉRIFIER LES CAUSES: 3 - 5
14.
FORTE QUANTITÉ DE COMBUSTIBLE
15.
MAUVAISE QUALITÉ DU COMBUSTIBLE
LE FEU EST
TROP VIF
16.
AMENÉE D'AIR PARASITE
17.
UTILISATION DE BOIS DE SECTION TROP PETITE
18.
DYSFONCTIONNEMENT DE LA BOITE À AIR
VÉRIFIER LES CAUSES: 5 - 7 - 9 - 10 - 11 - 12
LA VITRE NOIRCIT
19.
PROPRETÉ DE LA VITRE AVANT MISE À FEU
20.
ENTRÉE D'AIR PARASITE
» et suivez l'ordre des causes possibles.
constat
REMÈDES
•
PRATIQUER L'ALLUMAGE INVERSÉ, AVEC SUFFISAMMENT DE PETIT BOIS (VOIR CHAPITRE ALLUMAGE)
•
PRATIQUER L'ALLUMAGE INVERSÉ, AVEC BEAUCOUP DE PETIT BOIS (VOIR CHAPITRE ALLUMAGE)
•
PRATIQUER L'ALLUMAGE INVERSÉ, AVEC BEAUCOUP DE PETIT BOIS (VOIR CHAPITRE ALLUMAGE)
•
ATTENDRE DE MEILLEURES CONDITIONS
•
AUGMENTER L'APPORT D'AIR DANS LE LOCAL (OUVRIR PORTE, FENÊTRE ET/OU ÉTEINDRE TOUT SYSTÈME D'ASPIRATION)
•
VÉRIFIER LA POSITION
•
FAIRE UN TEST À OUVERTURE MAXIMALE
•
PRÉVENIR L'INSTALLATEUR
•
APPLIQUER LE REMÈDE CORRESPONDANT
•
AUGMENTER LA QUANTITÉ
•
LE REMPLACER PAR UN COMBUSTIBLE PLUS SEC
•
APPLIQUER LE REMÈDE CORRESPONDANT
•
AJOUTER DU COMBUSTIBLE PLUS SEC
•
AUGMENTER AU MINIMUM À LA CHARGE NOMINALE
•
UTILISER DU BOIS FENDU SANS ÉCORCE DE SECTION ADÉQUATE ET CORRECTEMENT DISPOSÉ
•
CONTROLER LE MOUVEMENT DU CLAPET D'AIR MOBILE
•
VÉRIFIER LA PROPRETÉ ET LE BON DIMENSIONNEMENT DE LA PRISE D'AIR
•
APPLIQUER LE REMÈDE CORRESPONDANT
•
RESPECTER LA CHARGE NOMINALE
•
UTILISER DU BOIS FENDU SANS ÉCORCE DE SECTION ADÉQUATE ET CORRECTEMENT DISPOSÉ
•
VÉRIFIER LA FERMETURE ET L'ÉTANCHÉITÉ DE LA PORTE DU FOYER ET DU CENDRIER
•
UTILISER DES BOIS DE SECTION DE +-12 À 15 CM
•
CONTROLER LE MOUVEMENT DU CLAPET D'AIR MOBILE
•
APPLIQUER LE REMÈDE CORRESPONDANT
•
NETTOYER SOIGNEUSEMENT LA VITRE
•
VÉRIFIER L'ÉTANCHÉITÉ DE LA PORTE
39