CAUTION – Make sure that the pump's
power cable does not hinder the proper fun-
ction / movement of the pump's float switch.
6. If required, connect any additional inlets
to the body of the Minilift making sure that
these inlets will not affect the function of
the pump's float switch.
7. Insert and glue the outgoing pressure
pipe (DN 40)(according to DIN 8063) insi-
de the outlet portion of the Minilift (#7 &
#6) (glue is supplied). Make sure that the
outgoing pressure pipe is securely instal-
led.
8. The Minilift (art.no. 28560) is ventilated
through the charcoal filter located on the
Minilift cover. If desired, a separate venti-
lation pipe can also be run to the buil-
ding's main ventilation pipe or directly to
the roof.
3. Installation
3.3 Additional inlets
Connection of lateral inlets or cable con-
duits (for concrete floor installation) size
Additional inlets can be connected to the
DN 50.
chamber of the Minilift by cutting out preci-
sion DN 50 holes with the KESSEL drill
attachment (Order # 50100). Please make
sure that any additional inlets connected to
the Minilift chamber do not interere with the
Illustration of hole drilling and inlet connection for additional lateral inlet (DN 50).
functioning of the pump's float switch. Plea-
se note that a minimum height of 60 mm
should be maintained between the inlet
level of all pipes and the bottom of the
chamber.
Please note: The float switch operation/
movement should not be blocked by any
additional lateral inlet (DN 50).
20