Configuring the Heat Pump Heating System
System-specific parameters
Duration of party mode in hours
After the set period has elapsed, the system
returns automatically to automatic operation.
The value for the raise is set in the menu
"Heating circuit 1 – Raise".
Duration of vacation mode in days
After the set period has elapsed, the system
returns automatically to automatic operation.
The value for the lowering is set in the menu
"Heating circuit 1 – Lower".
Level for setting the heat pump
This setting is dependent on the heat pump
type. Refer to the installation and operating
instructions of the heat pump or the heat
pump's type plate for the relevant number.
Settings for lowering the ventilator speed.
Lowering causes an output reduction of approx.
15%.
Settings of times during which the ventilator
speed is to be lowered.
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active when the speed is lowered.
Operations to lower the temperature that
exceed a weekday are activated or deactivated
at the end of each day accordingly.
Setting to determine whether pressure sensors
are present in the refrigerating circuit of the
heat pump:
Setting to determine whether the thermal
energy of the heat pump is to be measured by
an external thermal energy meter or the internal
thermal energy meter.
Enter the power output of the heat pump at the
standard measuring point according to the type
plate.
Setting the lower operating limit for the use of
the ground water as heat source or for waste
heat reduction via intermediate heat exchanger
Has flow rate monitoring been implemented in
the primary circuit?
Settings for the 2nd heat generator to
supplement heat pump heating operation in
bivalent and mono energy systems
The 2nd heat generator is only necessary from
a particular limit temperature onwards,
depending on the dimensioning of the heat
pump system. The 2nd heat generator is not
switched on until the temperature sinks below
the set limit temperature.
A variably-regulated 2nd heat generator has its
own external temperature-guided regulation.
Full volume can flow through it when required.
A constantly-regulated 2nd heat generator is
set to a constant temperature. The mixer
control is active.
Setting range
Display
0
Always
... 4 ...
72
0
Always
... 15 ...
150
Always
1
Always
2
Air-to-water heat
pump
Reversible HP
00:00
Air-to-water heat
pump
...
23:59
Reversible HP
N
Air-to-water heat
pump
T1
Reversible HP
T2
Y
Yes
Air-to-water heat
pump
No
External
Thermal
energymeter
Internal
Sensor
Thermal
energymeter
Sensor
Internal
-8 °C
Brine HP
... 8 °C ...
+15 °C
No
Brine HP
Yes
Bivalent or mono
energy
-20 °C
Bivalent or mono
energy
... -5 °C ...
+20 °C
Variable
Bivalent
Constant
6.1
EN-11