Télécharger Imprimer la page
Dimplex WI 10TU Instructions D'utilisation Et D'installation
Dimplex WI 10TU Instructions D'utilisation Et D'installation

Dimplex WI 10TU Instructions D'utilisation Et D'installation

Pompe a chaleur eau-eau pour installation interieure

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

WI 10TU
WI 14TU
WI 18TU
WI 22TU
Montage- und
Gebrauchsanweisung
Wasser-Wasser-
Wärmepumpe
für Innenaufstellung
Bestell-Nr. | Order no. | No de commande: 452235.66.21
Installation and
Operating Instruction
Water-to-Water
Heat Pump for
Indoor Installation
Glen
Dimplex
Thermal
Solutions
Instuctions d'installation
et d'utilisation
Pompe à chaleur
eau-eau pour
installation intérieure
DE | EN | FR · FD 9912
Dimplex

Publicité

loading

Sommaire des Matières pour Dimplex WI 10TU

  • Page 1 Glen Dimplex Thermal Solutions Dimplex WI 10TU WI 14TU WI 18TU WI 22TU Montage- und Installation and Instuctions d‘installation Gebrauchsanweisung Operating Instruction et d‘utilisation Wasser-Wasser- Water-to-Water Pompe à chaleur Wärmepumpe Heat Pump for eau-eau pour für Innenaufstellung Indoor Installation installation intérieure Bestell-Nr.
  • Page 3: Table Des Matières

    WI 10TU - WI 22TU Deutsch Inhaltsverzeichnis Bitte sofort lesen ............................DE-2 1.1 Wichtige Hinweise ................................DE-2 1.2 Bestimmungsgemäßer Gebrauch ..........................DE-2 1.3 Gesetzliche Vorschriften und Richtlinien.........................DE-2 1.4 Energiesparende Handhabung der Wärmepumpe ....................DE-3 Verwendungszweck der Wärmepumpe ....................DE-3 2.1 Anwendungsbereich...............................DE-3 2.2 Arbeitsweise..................................DE-3 Grundgerät..............................DE-3 Zubehör .................................DE-4 4.1 Fernbedienung..................................DE-4...
  • Page 4: Bitte Sofort Lesen

    Deutsch WI 10TU - WI 22TU ACHTUNG! Bitte sofort lesen Vor Öffnen des Gerätes sind alle Stromkreise spannungsfrei zu schalten. 1.1 Wichtige Hinweise 1.2 Bestimmungsgemäßer ACHTUNG! Gebrauch Für den Betrieb und die Wartung einer Wärmepumpe sind die rechtlichen Anforderungen des Landes einzuhalten, in dem Dieses Gerät ist nur für den vom Hersteller vorgesehenen Ver-...
  • Page 5: Energiesparende Handhabung Der Wärmepumpe

    WI 10TU - WI 22TU Deutsch 1.4 Energiesparende Handhabung Grundgerät der Wärmepumpe Das Grundgerät besteht aus einer anschlussfertigen Wärme- pumpe für Innenaufstellung mit Gehäuse, Schaltraum und inte- Durch das Betreiben dieser Wärmepumpe tragen Sie zur Scho- griertem Wärmepumpenmanager. Der Kältekreis ist „herme- nung unserer Umwelt bei.
  • Page 6: Zubehör

    Deutsch WI 10TU - WI 22TU Zubehör Transport Zum Transport auf ebenem Untergrund eignet sich ein Hubwa- 4.1 Fernbedienung gen. Muss die Wärmepumpe auf unebenem Untergrund oder über Treppen befördert werden, kann dies mit Tragriemen ge- Als Komforterweiterung ist im Sonderzubehör eine Fernbedien- schehen.
  • Page 7: Aufstellung

    WI 10TU - WI 22TU Deutsch 7.2 Heizungsseitiger Anschluss Aufstellung ACHTUNG! 6.1 Allgemeine Hinweise Vor Anschluss der Wärmepumpe Heizungsanlage spülen. Die Wasser/Wasser-Wärmepumpe muss in einem frostfreien Bevor die heizwasserseitigen Anschlüsse der Wärmepumpe er- und trockenen Raum auf einer ebenen, glatten und waagerech- folgen, muss die Heizungsanlage gespült werden, um eventuell...
  • Page 8: Wärmequellenseitiger Anschluss

    Deutsch WI 10TU - WI 22TU 7.4.1 Fühlerkennlinien Mindestheizwasserdurchsatz Der Mindestheizwasserdurchsatz der Wärmepumpe ist in jedem Betriebszustand der Heizungsanlage sicherzustellen. Temperatur in °C Dieses kann z.B. durch Installation eines doppelt differenz- NTC-2 in k 14,6 11,4 drucklosen Verteilers oder eines Überströmventiles erreicht NTC-10 in k...
  • Page 9: Verteilsystem Hydraulik

    WI 10TU - WI 22TU Deutsch 7.4.2 Montage des 7.4.4 Verteilsystem Hydraulik Außentemperaturfühlers Kompaktverteiler und Doppelt differenzdruckloser Verteiler fungieren als Schnittstelle zwischen der Wärmepumpe, dem Der Temperaturfühler muss so angebracht werden, dass sämt- Heizungsverteilsystem, dem Pufferspeicher und evtl. auch dem liche Witterungseinflüsse erfasst werden und der Messwert...
  • Page 10: Elektrischer Anschluss

    Deutsch WI 10TU - WI 22TU 7.5 Elektrischer Anschluss Das EVU-Sperrschütz (K22) mit 3 Hauptkontakten (1/3/5 / / 2/4/6) und einem Hilfskontakt (Schließer 13/14) ist ent- sprechend der Wärmepumpenleistung auszulegen und 7.5.1 Allgemein bauseits beizustellen. Der Schließer-Kontakt des EVU-Sperrschütz (13/14) wird Sämtliche elektrische Anschlussarbeiten dürfen nur von einer...
  • Page 11: Anschluss Von Elektronisch Geregelten Umwälzpumpen

    WI 10TU - WI 22TU Deutsch 8.3 Vorgehensweise bei 7.5.3 Anschluss von elektronisch geregelten Umwälzpumpen Inbetriebnahme Elektronisch geregelte Umwälzpumpen weisen hohe Anlauf- Die Inbetriebnahme der Wärmepumpe erfolgt über den ströme auf, die unter Umständen die Lebenszeit des Wärme- Wärmepumpenmanager. pumpenmanagers verkürzen können. Aus diesem Grund, ist zwischen dem Ausgang des Wärmepumpenmanagers und der...
  • Page 12: Pflege / Reinigung

    Deutsch WI 10TU - WI 22TU 9.4 Anforderungen an die Pflege / Reinigung Wasserqualität 9.1 Pflege Um eine Verockerung der Wärmepumpenanlage zu verhindern, dürfen keine absetzbaren Stoffe im Grundwasser enthalten Um Betriebsstörungen durch Schmutzablagerungen in den sein und die EISEN- (< 0,2 mg/l) und MANGAN- (< 0,1 mg/l) Wärmetauschern zu vermeiden, ist dafür Sorge zu tragen, dass...
  • Page 13: Geräteinformation

    WI 10TU - WI 22TU Deutsch 12 Geräteinformation Typ- und Verkaufsbezeichnung WI 10TU WI 14TU Bauform Ausführung Universal Universal Regler intern intern Wärmemengenzählung integriert integriert Aufstellungsort / Schutzart nach EN 60 529 Innen / IP 21 Innen / IP 21...
  • Page 14 Deutsch WI 10TU - WI 22TU Typ- und Verkaufsbezeichnung WI 18TU WI 22TU Bauform Wärmequelle Wasser Wasser Ausführung Universal Universal Regler WPM EconPlus integriert WPM EconPlus integriert Wärmemengenzählung integriert integriert Aufstellungsort Innen Innen Leistungsstufen Einsatzgrenzen Heizwasser-Vorlauf °C 20 bis 62 ± 2 20 bis 62 ±...
  • Page 15: Produktinformationen Gemäß Verordnung (Eu) Nr.813/2013, Anhang Ii, Tabelle 2

    Kontakt Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) Für Heizgeräte und Kombiheizgeräte mit Wärmepumpe ist die Wärmenennleistung Prated gleich der Auslegungslast im Heizbetrieb Pdesingh und die Wärmenennleistung eines Zusatzheizgerätes Psup gleich der zusaätzlichen Heizleistung sup(Tj ).
  • Page 16 Täglicher Brennstoffverbrauch Kontakt Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) Für Heizgeräte und Kombiheizgeräte mit Wärmepumpe ist die Wärmenennleistung Prated gleich der Auslegungslast im Heizbetrieb Pdesingh und die Wärmenennleistung eines Zusatzheizgerätes Psup gleich der zusaätzlichen Heizleistung sup(Tj ).
  • Page 17 Täglicher Brennstoffverbrauch Kontakt Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) Für Heizgeräte und Kombiheizgeräte mit Wärmepumpe ist die Wärmenennleistung Prated gleich der Auslegungslast im Heizbetrieb Pdesingh und die Wärmenennleistung eines Zusatzheizgerätes Psup gleich der zusaätzlichen Heizleistung sup(Tj ).
  • Page 18 Täglicher Brennstoffverbrauch Kontakt Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) Für Heizgeräte und Kombiheizgeräte mit Wärmepumpe ist die Wärmenennleistung Prated gleich der Auslegungslast im Heizbetrieb Pdesingh und die Wärmenennleistung eines Zusatzheizgerätes Psup gleich der zusaätzlichen Heizleistung sup(Tj ).
  • Page 19: Garantieurkunde

    WI 10TU - WI 22TU Deutsch Eine Verlängerung der Garantie auf 60 Monate oder mehr für Hei- 14 Garantieurkunde zungs-Wärmepumpen und zentrale Wohnungslüftungsgeräte ab dem Datum der Inbetriebnahme wird gemäß den nachfolgenden Glen Dimplex Thermal Solutions Bedingungen gewährt Garantieurkunde GDTS (Heizungs-Wärmepumpen, Zentrale Wohnungslüftungsgeräte)
  • Page 20 Deutsch WI 10TU - WI 22TU DE-18 452235.66.21 · FD 9912 www.gdts.one...
  • Page 21 WI 10TU - WI 22TU English Table of contents Please Read Immediately ..........................EN-2 1.1 Important Information ..............................EN-2 1.2 Intended Use ..................................EN-2 1.3 Legal Regulations and Directives ..........................EN-2 1.4 Energy-Efficient Use of the Heat Pump ........................EN-3 Purpose of the Heat Pump........................EN-3 2.1 Application ..................................EN-3...
  • Page 22: Please Read Immediately

    English WI 10TU - WI 22TU ATTENTION! Please Read Immediately Disconnect all electrical circuits from the power source prior to opening the device. 1.1 Important Information 1.2 Intended Use ACHTUNG! This device is only intended for use as specified by the manu- When operating or maintaining a heat pump, the legal requirements of the facturer.
  • Page 23: Energy-Efficient Use Of The Heat Pump

    WI 10TU - WI 22TU English 1.4 Energy-Efficient Use of the Heat Basic Device Pump The basic device consists of a ready-to-use heat pump for in- door installation, complete with casing, switch box and inte- By operating this heat pump you are helping to protect our en- grated Heat pump manager.
  • Page 24: Accessories

    English WI 10TU - WI 22TU Accessories Transport A lift truck is suited for transporting the unit on a level surface. 4.1 Remote control Carrying straps may be used if the heat pump needs to be transported on an uneven surface or carried up or down stairs.
  • Page 25: Set-Up

    WI 10TU - WI 22TU English 7.2 Heating System Connection Set-up ATTENTION! 6.1 General Information Flush the heating system prior to connecting the heat pump. The compact water-to-water heat pump must be installed in a Before connecting the heating water system to the heat pump, frost-free, dry room on an even, smooth and horizontal surface.
  • Page 26: Heat Source Connection

    English WI 10TU - WI 22TU 7.4.1 Sensor characteristic curves Minimum heating water flow rate The minimum heating water flow rate through the heat pump must be assured in all operating states of the heating system. Temperature in °C This can be accomplished, for example, by installing either a NTC-2 in k...
  • Page 27: Mounting The External Temperature Sensor

    WI 10TU - WI 22TU English 7.4.2 Mounting the external temperature 7.4.4 Hydraulic distribution system sensor The compact manifold and the dual differential pressureless manifold function as an interface between the heat pump, the The temperature sensor must be mounted in such a way that all...
  • Page 28: Electrical Connection

    English WI 10TU - WI 22TU 7.5 Electrical connection The utility blocking contactor(K22) with 3 main contacts (1/3/5 // 2/4/6) and an auxiliary contact (NO contact 13/ 14) should be dimensioned according to the heat pump 7.5.1 General output and must be supplied by the customer.
  • Page 29: Commissioning

    WI 10TU - WI 22TU English 8.3 Start-up Procedure 7.5.3 Connecting an electronically regulated circulating pump The heat pump is started up via the heat pump manager. Electronically regulated circulating pumps have high starting ATTENTION! currents, which may shorten the service life of the heat pump The heat pump must be started up in accordance with the manager.
  • Page 30: Maintenance And Cleaning

    English WI 10TU - WI 22TU 9.4 Water Quality Requirements Maintenance and Cleaning The ground water should not contain any substances that 9.1 Maintenance could form deposits. The limit values for iron (< 0.2 mg/l) and manganese (< 0.1 mg/l) must be adhered to prevent iron ochre To prevent faults due to sediment in the heat exchangers, care sedimentation in the heat pump system.
  • Page 31: Device Information

    WI 10TU - WI 22TU English 12 Device Information Type and order code WI 10TU WI 14TU Design Model Universal Universal Controller internal internal Thermal energy metering Integrated Integrated Installation location / degree of protection according to EN 60 529...
  • Page 32 English WI 10TU - WI 22TU Type and order code WI 18TU WI 22TU Design Heat source Water Water model Universal Universal Contr. WPM EconPlus WPM EconPlus Thermal energy metering Integrated Integrated Installation location Indoors Indoors Performance levels Operating limits Heating water flow °C...
  • Page 33: Product Information As Per Regulation (Eu) No 813/2013, Annex Ii, Table 2

    Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 34 Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 35 Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 36 Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 37 WI 10TU - WI 22TU Français Table des matières A lire immédiatement !..........................FR-2 1.1 Remarques importantes ..............................FR-2 1.2 Utilisation conforme................................ FR-2 1.3 Dispositions légales et directives..........................FR-2 1.4 Utilisation de la pompe à chaleur pour économiser de l'énergie..............FR-3 Utilisation de la pompe à...
  • Page 38: Lire Immédiatement

    Français WI 10TU - WI 22TU 1.2 Utilisation conforme A lire immédiatement ! Cet appareil ne doit être employé que selon les conditions d'uti- 1.1 Remarques importantes lisation prévues par le fabricant. Toute autre utilisation est considérée comme non conforme. La documentation accom- pagnant les projets doit également être prise en compte.Toute...
  • Page 39: Utilisation De La Pompe À Chaleur Pour Économiser De L'énergie

    WI 10TU - WI 22TU Français 1.4 Utilisation de la pompe à Appareil de base chaleur pour économiser de Il s'agit d'une pompe à chaleur pour installation intérieure, prête à brancher, avec boîtier, compartiment électrique et gestion- l'énergie naire de pompe à chaleur intégré. Le circuit frigorifique est «...
  • Page 40: Accessoires

    Français WI 10TU - WI 22TU Accessoires Transport Le transport par chariot élévateur convient bien à un déplace- 4.1 Télécommande ment sur surface plane. Si la pompe à chaleur doit être convoyée sur une surface non plane ou dans des escaliers, il est Une station de télécommande est disponible comme acces-...
  • Page 41: Installation

    WI 10TU - WI 22TU Français 7.2 Branchement côté installation Installation de chauffage 6.1 Généralités ATTENTION ! La pompe à chaleur eau/eau doit être installée dans un local Rincer l'installation de chauffage avant de brancher la pompe sec à l'abri du gel, sur une surface plane, lisse et horizontale. Le à...
  • Page 42: Raccordement Côté Source De Chaleur

    Français WI 10TU - WI 22TU 7.4.1 Courbes caractéristiques de la sonde Débit d'eau de chauffage minimum Quel que soit l'état de fonctionnement de l'installation de chauffage, un débit d'eau de chauffage minimum doit être ga- Température en °C ranti dans la pompe à chaleur. Cela peut par ex. être obtenu par NTC-2 en k...
  • Page 43: Montage De La Sonde De Température Extérieure

    WI 10TU - WI 22TU Français 7.4.2 Montage de la sonde de température 7.4.4 Système de distribution hydraulique extérieure Le distributeur compact et le distributeur double sans pression différentielle servent d'interface entre la pompe à chaleur, le La sonde de température doit être placée de telle sorte qu’elle système de distribution de chauffage, le ballon tampon et...
  • Page 44: Branchements Électriques

    Français WI 10TU - WI 22TU 7.5 Branchements électriques La ligne d’alimentation (L/N/PE ~230 V, 50 Hz) du gestion- naire WPM doit être sous tension permanente. Elle est, de ce fait, à saisir avant le contacteur de blocage de la société...
  • Page 45: Branchement Du Circulateur À Régulation Électronique

    WI 10TU - WI 22TU Français 8.3 Procédures à suivre lors de la 14) La sonde d'eau chaude sanitaire (R3) est fournie avec le ballon d'eau chaude sanitaire et reliée aux bornes X3/GND mise en service et X3/R3. La mise en service de la pompe à chaleur s’effectue via le ges- 7.5.3 Branchement du circulateur à...
  • Page 46: Entretien / Nettoyage

    Français WI 10TU - WI 22TU 9.4 Qualité de l’eau Entretien / nettoyage L’eau de la nappe phréatique ne doit contenir aucune subs- 9.1 Entretien tance susceptible de se déposer et les valeurs limites de FER- (< 0,2 mg/l) et MANGANESE (< 0,1 mg/l) doivent être respec- Pour éviter des dysfonctionnements dus à...
  • Page 47: Informations Sur Les Appareils

    WI 10TU - WI 22TU Français 12 Informations sur les appareils Désignation technique et commerciale WI 10TU WI 14TU Type Version universelle universelle Régulateur interne interne Calorimètre intégré intégré Emplacement / degré de protection selon EN 60 529 à l’intérieur / IP 21 à...
  • Page 48: Désignation Technique Et Référence De Commande

    Français WI 10TU - WI 22TU Désignation technique et référence de commande WI 18TU WI 22TU Design Source de chaleur Version Universelle Universelle Régulateur Gestionnaire de PAC EconPlus Gestionnaire de PAC EconPlus Calorimètre Intégré Intégré Lieu d’emplacement À l'intérieur À l'intérieur...
  • Page 49: Informations Sur Le Produit Conformément Au Règlmenet (Ue) N° 813

    Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach Coordonnées de contact (*) Pour les dispositifs de chauffage des locaux par pompe à chaleur et les dispositifs de chauffage mixtes par pompe à chaleur, la puissance thermique nominale Prated est égale à...
  • Page 50 Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach Coordonnées de contact (*) Pour les dispositifs de chauffage des locaux par pompe à chaleur et les dispositifs de chauffage mixtes par pompe à chaleur, la puissance thermique nominale Prated est égale à...
  • Page 51 Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach Coordonnées de contact (*) Pour les dispositifs de chauffage des locaux par pompe à chaleur et les dispositifs de chauffage mixtes par pompe à chaleur, la puissance thermique nominale Prated est égale à...
  • Page 52 Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach Coordonnées de contact (*) Pour les dispositifs de chauffage des locaux par pompe à chaleur et les dispositifs de chauffage mixtes par pompe à chaleur, la puissance thermique nominale Prated est égale à...
  • Page 53: Anhang / Appendix / Annexesappendice

    Anhang / Appendix / Annexes Maßbild / Dimension Drawing / Schéma coté ..................A-II 1.1 Maßbild / Dimension Drawing / Schéma coté WI 10TU - WI 18TU ..............A-II 1.2 Maßbild / Dimension Drawing / Schéma coté WI 22TU ..................A-III Diagramme / Diagrams / Diagrammes ....................A-IV 2.1 Kennlinien / Characteristic Curves / Courbes caractéristiques WI 10TU .............
  • Page 54: Maßbild / Dimension Drawing / Schéma Coté

    Anhang · Appendix · Annexes WI 10TU - WI 22TU 1 Maßbild / Dimension Drawing / Schéma coté 1.1 Maßbild / Dimension Drawing / Schéma coté WI 10TU - WI 18TU A-II 452235.66.21 · FD 9912 www.gdts.one...
  • Page 55: Maßbild / Dimension Drawing / Schéma Coté Wi 22Tu

    WI 10TU - WI 22TU Anhang · Appendix · Annexes 1.2 Maßbild / Dimension Drawing / Schéma coté WI 22TU www.gdts.one 452235.66.21 · FD 9912 A-III...
  • Page 56: Diagramme / Diagrams / Diagrammes

    Anhang · Appendix · Annexes WI 10TU - WI 22TU 2 Diagramme / Diagrams / Diagrammes 2.1 Kennlinien / Characteristic Curves / Courbes caractéristiques WI 10TU Heizleistung in [kW] Wasseraustrittstemperatur in [°C] Heating capacity in [kW] Water outflow temperature in [°C] Puissance de chauffage en [kW] Température de sortie de l’eau en [°C]...
  • Page 57: Kennlinien / Characteristic Curves / Courbes Caractéristiques Wi 14Tu

    WI 10TU - WI 22TU Anhang · Appendix · Annexes 2.2 Kennlinien / Characteristic Curves / Courbes caractéristiques WI 14TU Wasseraustrittstemperatur in [°C] Heizleistung in [kW] Water outflow temperature in [°C] Heating capacity in [kW] Température de sortie de l’eau en [°C] Puissance de chauffage en [kW] Bedingungen ·...
  • Page 58: Kennlinien / Characteristic Curves / Courbes Caractéristiques Wi 18Tu

    Anhang · Appendix · Annexes WI 10TU - WI 22TU 2.3 Kennlinien / Characteristic Curves / Courbes caractéristiques WI 18TU Heizleistung in [kW] Wasseraustrittstemperatur in [°C] Heating capacity in [kW] Water outflow temperature in [°C] Puissance de chauffage en [kW] Température de sortie de l’eau en [°C]...
  • Page 59: Kennlinien / Characteristic Curves / Courbes Caractéristiques Wi 22Tu

    WI 10TU - WI 22TU Anhang · Appendix · Annexes 2.4 Kennlinien / Characteristic Curves / Courbes caractéristiques WI 22TU Heizleistung in [kW] Wasseraustrittstemperatur in [°C] Water outflow temperature in [°C] Heating capacity in [kW] Puissance de chauffage en [kW] Température de sortie de l’eau en [°C]...
  • Page 60: Einsatzgrenzendiagramm / Operating Limits Diagram / Diagramme Des Seuils D'utilisation

    Anhang · Appendix · Annexes WI 10TU - WI 22TU 2.5 Einsatzgrenzendiagramm / Operating limits diagram / Diagramme des seuils d'utilisation Wasseraustritt (+/- 2 K) Water outlet (+/- 2 K) Sortie d'eau (+/- 2 K) Wärmequelleneintrittstemperatur [°C] Heat source inlet temperature [°C] Température d'entrée de la source de chaleur [°C]...
  • Page 61: Stromlaufpläne / Circuit Diagrams / Schémas Électriques

    WI 10TU - WI 22TU Anhang · Appendix · Annexes 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung / Control / Commande www.gdts.one 452235.66.21 · FD 9912 A-IX...
  • Page 62 Anhang · Appendix · Annexes WI 10TU - WI 22TU 3.2 Steuerung / Control / Commande 452235.66.21 · FD 9912 www.gdts.one...
  • Page 63: Last / Load / Charge

    WI 10TU - WI 22TU Anhang · Appendix · Annexes 3.3 Last / Load / Charge www.gdts.one 452235.66.21 · FD 9912 A-XI...
  • Page 64: Anschlussplan / Circuit Diagram / Schéma Électrique

    Anhang · Appendix · Annexes WI 10TU - WI 22TU 3.4 Anschlussplan / Circuit Diagram / Schéma électrique A-XII 452235.66.21 · FD 9912 www.gdts.one...
  • Page 65 WI 10TU - WI 22TU Anhang · Appendix · Annexes 3.5 Anschlussplan / Circuit Diagram / Schéma électrique www.gdts.one 452235.66.21 · FD 9912 A-XIII...
  • Page 66: Legende / Legend / Légende

    Anhang · Appendix · Annexes WI 10TU - WI 22TU 3.6 Legende / Legend / Légende Brücke EVU-Sperre: muß eingelegt werden, wenn Utility block (EVU) bridge must be inserted if no Pont de blocage de la société d'électricité, à insé- kein EVU-Sperrschütz vorhanden ist...
  • Page 67 WI 10TU - WI 22TU Anhang · Appendix · Annexes Warmwasserfühler Hot water sensor Sonde d’eau chaude Fühler für 2ten Heizkreis Sensor for heating circuit 2 Sonde pour 2e circuit de chauffage Vorlauffühler Primärkreis Flow sensor for primary circuit Sonde aller circuit primaire...
  • Page 68: Hydraulisches Einbindungsschema / Hydraulic Integration Diagram / Schéma D'intégration Hydraulique

    Anhang · Appendix · Annexes WI 10TU - WI 22TU 4 Hydraulisches Einbindungsschema / Hydraulic integration diagram / Schéma d'intégration hydraulique 4.1 Monovalente Wärmepumpenanlage mit einem Heizkreisen / Monovalent heat pump system with one heating circuits / Installation monovalente de pompe à...
  • Page 69: Monovalente Wärmepumpenanlage Mit Einem Heizkreisen Und Warmwasserbereitung / Monovalent

    WI 10TU - WI 22TU Anhang · Appendix · Annexes 4.2 Monovalente Wärmepumpenanlage mit einem Heizkreisen und Warmwasserbereitung / Monovalent heat pump system with one heating circuits and domestic hot water preparation / Installation monovalente de pompe à chaleur avec une circuits de chauffage et production d'eau chaude sanitaire www.gdts.one...
  • Page 70: Legende / Legend / Légende

    Anhang · Appendix · Annexes WI 10TU - WI 22TU 4.3 Legende / Legend / Légende Rückschlagventil Check valve Clapet anti-retour Absperrventil Shutoff valve Robinet d’arrêt Schmutzfänger Dirt trap Filtre Umwälzpumpe Circulating pump Circulateur Ausdehnungsgefäß Expansion vessel Vase d´expansion Vanne commandée par...
  • Page 71: Konformitätserklärung / Declaration Of Conformity / Déclaration De Conformité

    WI 10TU - WI 22TU Anhang · Appendix · Annexes 5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité Die aktuelle CE-Konformitätserklärung finden sie als Download unter: You can find and download the current CE conformity declaration at: Vous pouvez télécharger la déclaration de conformité CE actuelle sous : https://gdts.one/wi10tu...
  • Page 72 Glen Dimplex Deutschland GmbH Irrtümer und Änderungen vorbehalten. Geschäftsbereich GDTS Subject to alterations and errors. Am Goldenen Feld 18 Sous réserve d’erreurs et modifications. D-95326 Kulmbach +49 (0) 9221 709 924545 www.gdts.one...

Ce manuel est également adapté pour:

Wi 14tuWi 18tuWi 22tu