Configuring the Heat Pump Heating System
System-specific parameters
Sets the desired hot water temperature which is
to be reached during thermal disinfection
For each day of the week, it is possible to select
whether thermal disinfection is desired at the
set start time.
The circulation pump is started using a paddle
flow switch, for example. When the paddle flow
switch returns to the original position, the
circulation pump operates for the duration of
the set time.
The circulation pump is controlled by a timer
function.
Sets the times at which the circulation pump is
to be activated.
For each day of the week, it is possible to select
whether the circulation pump is activated at the
set start time.
By setting Reset to "Yes", the maximum
calculated domestic hot water temperatures in
HP operation are reset to a value of 65 °C. The
setting is automatically reset to "No".
Sets the preparation of swimming pool water
Sets the external temperature below which
domestic hot water preparation is carried out
with 2 compressors in 2-compressor heat
pumps
Sets the desired swimming pool temperature
Sets the desired swimming pool temperature
with parallel cooling operation
The hysteresis of the swimming pool set
temperature forms the neutral zone below
which a swimming pool request will be issued.
Sets whether the waste heat recovery during
cooling is dependent on the switching status of
the thermostat or in continuous operation
Sets the time programs for blocking swimming
pool water preparation
Sets the times at which a swimming pool block
is to take place
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active for a swimming pool block.
Blocks that exceed a weekday are activated or
deactivated at the end of each day accordingly.
Setting range
Display
60 °C
Hot water
... 65 °C ...
Sensor
85 °C
Bivalent or flange
heater
N
Hot water
Y
Sensor
Bivalent or flange
heater
1 min
Circulation
... 5 ...
Pulse
15 min
Circulation
Time
00:00
Circulation
23:59
Time
N
Circulation
Y
Time
No
Hot water
Yes
Sensor
Swimming pool
-30 °C
Swimming pool
... 25 °C ...
2 compressors
-35 °C
(10 °C HT)
5 °C
Swimming pool
... 25 °C ...
Reversible HP
60 °C
Sensor
5 °C
Swimming pool
... 25 °C ...
Reversible HP
60 °C
Additional heat
exchanger
Sensor
1K
Swimming pool
...
Reversible HP
20K
Sensor
No
Swimming pool
Yes
Reversible HP
Additional heat
exchanger
Swimming pool
00:00
Swimming pool
...
23:59
N
Swimming pool
T1
T2
Y
6.1
EN-17