ENG
16. Technical data
NOTE: The data given on the module rat-
ing plate attached to the underside of the
module apply.
16.1 Compatibility
Th e m o d u l e is compatible with all
Waldmann luminaires equipped with the
following controls and firmware versions:
Dimmable
Version VFP 4.4 D (and higher)
PIR sensor
Version VFS 4.3 E (and higher)
Version VFS 4.4 F (and higher)
HFMD sensor
Version VFP 4.5 H (and higher)
Version VFP 4.9 A (and higher)
16.2 Admissible temperatures
Designation
Ambient temper-
ature in operation
Storage temper-
ature
Tab. 4: Admissible temperatures.
16.3 Electrical values
Designation
Input voltage
range
Power consump-
tion
Power supply
Tab. 5: System requirements
58
Value
0°C...55°C
-25°C...75°C
Value
5-6 V DC
250 mW
(max. 280 mW)
Via
light control
16.4 Wireless data
Designation
Value
Wireless
Bidirectional
technology
EnOcean wireless com-
munication
Radio trans-
868.3 MHz
ceiver
For use in EU countries,
Switzerland, the Repub-
lic of China and the Sul-
tanate of Oman.
902.875 MHz
For use in the USA
Range
30 m in buildings
Tab. 6: Wireless specification
16.5 Classification
Designation
Value
III
Protection
class
Degree of
IP 20
protection
Operating
Continuous operation
mode
Tab. 7: Classification.
16.6 Symbols
Symbol
Designation
Protection class III
Operation with safety
extra low voltage (SELV)
CE conformity mark
including the code num-
ber of the Notified Body
FCC mark
EnOcean
wireless technology
Performing a reset