Connecting external receivers
Setting the Advanced Single Control
Fig. 29: DIP switch position for the Advanced
Single Control function
X Disconnect the luminaire from the
power supply.
X Set the DIP switch no. 1 to the "ON"
position, see Fig. 29.
X Set the DIP switches no. 2 and no. 3 to
the "OFF" position.
NOTE: The position of the DIP switch
no. 4 is irrelevant for this function.
X Reconnect the light to the power sup-
ply.
X Perform a teach-in for external receiv-
ers, see chapter 11.1 "Teach-in of exter-
nal receivers" , page 50.
X If the external function is not yet acti-
vated, activate the external function,
see chapter 11.3 "Activating and deacti-
vating the external function" , page 51.
Setting the Simple Group Control
NOTE: The swarm control must be acti-
vated for all luminaires of the desired group.
Fig. 30: DIP switch position for the Simple
Group Control function
X Disconnect the luminaire from the
power supply.
X Set the DIP switch no. 2 to the "ON"
position, see Fig. 30.
X Set the DIP switches no. 1 and no. 3 to
the "OFF" position.
NOTE: The position of the DIP switch
no. 4 is irrelevant for this function.
X Reconnect the light to the power sup-
ply.
X Perform a teach-in for external receiv-
ers, see chapter 11.1 "Teach-in of exter-
nal receivers" , page 50.
X If the external function is not yet acti-
vated, activate the external function
for the luminaire for which the external
receiver was taught in, see chapter 11.3
"Activating and deactivating the exter-
nal function" , page 51.
ENG
53