Les langues disponibles

BURNER USE

E
Burner operation is fully automatic.
N
the burner is started by closing the master switch and the control
panel switch. Correct burner operation is regulated using the com-
G
mand and control devices, as described in the chapter "Operation
description". The "lock" position is a safety position that the bur-
L
ner automatically assumes when a burner or system component
I
is not working properly. The burner may stay in the lock position
without any time limits. Locks may also be caused by temporary
S
inefficiencies. In this case, the burner will restart normally. It is
recommended to check for anomalies in the heating plant befo-
H
re restarting the burner. To release it, press the release button.
GENERAL DIAGRAM AIR REGULATION
INCORRECT REGULATION
Combustion air inlet with
very locked shutter
CORRECT REGULATION
Combustion air inlet with
very opened shutter
All manuals and user guides at all-guides.com
If locking continues to occur (3-4 times), do not continue with the
operation. Check that the fuel arrives normally to the burner and
ask for assistance from the after-sales service in your area.
Combustion head
Air flow large
opening
Control and fixing knobs of combustion head
Combustion head
Air flow quite locked.
Attention:
Avoid complete locking
22 / 30
0006080118_200811
Control and fixing knobs of combustion head
N° 8608/1