4.8 Cleaning
To reduce the risk of fire, keep the en-
gine, silencer, battery and fuel tank free
from grass, leaves and oil.
To reduce the risk of fire, regularly
check the machine for oil and/or fuel
leakage.
Clean the machine after each use. The following
instructions apply for cleaning:
• When washing the machine with water under
high pressure, do not point the jet directly at
axle seals, electrical components or hydraulic
valves.
• Do not spray water directly at the engine.
• Clean the engine with a brush and/or com-
pressed air.
• Clean the engine's cooling air intake (10, 11,
12:W).
5 MAINTENANCE
5.1 Service programme
In order to keep the machine in good condition as
regards reliability and operational safety as well as
from an environmental perspective, STIGA's Ser-
vice programme should be followed.
The contents of this programme can be found in
the attached service log.
Basic service must always be carried out by an au-
thorised workshop.
First service and intermediate service should be
carried out by an authorised workshop, but can
also be carried out by the user. The content of this
can be found in the service log and the actions are
described under "4 STARTING AND OPERA-
TION" as well as below.
Servicing carried out at an authorised workshop
guarantees professional work using genuine spare
parts.
At each basic service and intermediate service car-
ried out at an authorised workshop, the service log
is stamped. A service log presenting these services
is a valuable document that improves the ma-
chine's second-hand value.

5.2 Preparation

All service and all maintenance must be carried out
on a stationary machine with the engine switched
off.
Prevent the machine from rolling by al-
ways applying the parking brake.
Stop the engine.
58
ENGLISH
Prevent unintentional starting of the
engine by disconnecting the spark plug
cable(s) from the spark plug(s) and re-
moving the ignition key.
5.3 Tyre pressure
Adjust the air pressure in the tyres as follows:
Front: 0.6 bar (9 psi).
Rear: 0.4 bar (6 psi).
5.4 Changing engine oil
This section contains tables covering the different
engines that are included in STIGA's Pro range. To
facilitate reading, mark the data that applies to the
relevant machine/engine.
5.4.1 Change intervals
The table below states hours of operation and cal-
endar months. Carry out the relevant action at
whichever occurs first.
Machine
Unlimited, President,
(B&S)
Changing the oil
Excellent (B&S)
Changing the oil
Changing the filter
Power (Kohler)
Changing the oil
Changing the filter
Change the oil more frequently if the engine has to
operate in demanding conditions or if the ambient
temperature is high.
5.4.2 Engine Oil
Use synthetic oil according to the table below.
Machine
Unlimited,
President,
Excellent (B&S)
All temperatures
SAE 10W-40
Below -18° C
SAE 5W-30
Above 0° C
SAE 30
Power (Kohler)
Above 0° C
SAE 10W-40
Below 0° C
SAE 5W-20/30
Use oil without any additives.
1st time
Then at
intervals of
Hours of operation/
Calendar months
50 hours/
5 hours
12 months
Hours of operation/
Calendar months
50 hours/
5 hours
12 months
100 hours
Hours of operation/
Calendar months
-
100 hours
200 hours
Oil
Grade
Service-
class
SF
or higher
Grade
Service-
class
SG
or higher