H1/3 WHITE/BLUE 200 mA (-) channel 3 output
This wire provides a (-) 200 mA output whenever the transmitter button(s) controlling Channel 3 is pressed. This
output can be programmed to provide the following types of output (see System Features Learn Routine section):
I A validity output will send a signal as long as the transmission is received.
I A latched output will send a signal continuously when the Channel 3 transmitter button(s) is pressed and
will continue until Channel 3 is pressed again.
I A latched/reset with ignition output works similar to the latched output, but will also reset (output will
stop) when the ignition is turned on and then off.
I A 30-second timed output will send a signal for 30 seconds when the Channel 3 button(s) is pressed. This
output can be shut off during the 30-second period by pressing the Channel 3 button(s) again.
I This output can also be programmed to provide a second unlock pulse when the disarm button is pressed
within 15 seconds after disarming the system. This can be used to unlock the passenger doors when installing
progressive door locks.
IMPORTANT! Never use this wire to drive anything but a relay or a low-current input! This
transistorized output can only supply 200 mA, and connecting directly to a solenoid, motor, or other
high-current device will cause the module to fail.
NOTE: Many of the options that can be operated with this output require the addition of the
optional Relay Accessory Package (GM P/N 12495659).
H1/4 BLACK/WHITE high current output from on-board domelight supervision relay
Connect this wire directly to the domelight circuit in the vehicle. The on-board relay will drive circuits up to
20 amperes. The polarity of this output is determined by the connection of the H2/B input wire in the Door Lock
Relay Harness.
NOTE: If the H2/B input wire is not connected, there will be no output on this wire.
H1/5 GREEN (-) door trigger input, zone 3
Most vehicles use negative door trigger circuits. Connect the green wire to a wire which shows ground when any
door is opened. In vehicles with factory delays on the domelight circuit, there is usually a wire that is unaffected
by the delay circuitry. This wire will report Zone 3.
All manuals and user guides at all-guides.com
12 - English
NVSL4000