Timer Operation - Climadiff CLIMA18 Manuel D'utilisation

Masquer les pouces Voir aussi pour CLIMA18:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Timer operation

press the TIMER ON button can set the auto-on
time of the unit. And press the TIMER OFF button
can set the auto-off time of the unit.
To set the Auto-on time.
1. Press the TIMER ON button. The remote
SET TEMPERATURE( C)
AUTO
FAN
controller shows TIMER ON, the last Auto-on
COOL
HIGH
setting time and the signal "h" will be shown on
DRY
MED
HEAT
LOW
TIMER ON
the LCD display area. Now it is ready to reset the
Auto-on time to START the operation.
TEMP
2. Push the TIMER ON button again to set desired
Auto-on time. Each time you press the button,
ON/OFF FAN SPEED
MODE
the time increases in 30 minutes increments, up
SWING ECONOMY TIMER ON
to 10 hours, then at 1 hour increments up to 24
1
hours.
2
3. After setting the TIMER ON ,there will be a one-
half second delay before the remote controller
RESET LOCK
TIMER OFF
transmits the signal to the air conditioner. Then,
LED
DISPLAY
after approximately another 2 seconds, the
signal "h" will disappear and the set temperature
will re-appear on the LCD display window.
To set the Auto-off time.
1. Press the TIMER OFF button. The remote
controller shows TIMER OFF, the last Auto-off
setting time and the signal "h" will be shown on
the LCD display area. Now it is ready to
reset the Auto-off time to START the operation.
2. Push the TIMER OFF button again to set desired
Auto-off time. Each time you press the button,
the time increases in 30 minutes increments, up
to 10 hours, then at 1 hour increments up to 24
hours.
3. After setting the TIMER OFF ,there will be a one-
half second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "h" will disappear and the set temperature
will re-appear on the LCD display window.
All manuals and user guides at all-guides.com
9
IMPORTANT
The effective operation time set by the remote controller for the timer
function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0,
3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13,
14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24.
Example of Timer setting
TIMER ON
(Auto-on Operation)
h
The TIMER ON feature is useful when you want
the unit to turn on automatically before say when
TIMER ON
you return home. The air conditioner will automa-
tically
Example:
Off
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting of
6 hours later
starting operation time and the signal "h" will
show on the display area.
2. Press the TIMER ON button to display "6:0h" on
the TIMER ON display of the remote controller.
3. Wait for about 3 seconds and the digital display
area will show the temperature again. Now this
function is activated.
10
start
operating
at
the
set
time.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Clima19

Table des Matières