AIR CONDITIONER FEATURES
E LE CT RONI C CONT ROL OP E RATI NG INS T RUCT I ONS
Before you begin, thoroughly familiarize yourself with the control panel and remote controller
and all its functions, then follow the symbol for the functions you desire.
The unit can be controlled by the unit control panel alone or with the remote controller .
NOTE: This manual does not include Remote Controller Operations, see the <<Remote
Controller Instruction>> packed with the unit for details.
OPERATION PANEL OF THE AIR CONDITIONER
1
Power indicator
2
light
Fig.3
4
3
2
Timer mode indicator
light (set only by remote
controller)
6
MODE select button
1
MODE select button
Selects the appropriate operating mode.
Each time you press the button, a mode
is selected in a sequence that goes from
COOL, FAN and DRY .The mode indicator
light illuminates under the different mode
setting.
NOTE: On above modes, the unit operates the
auto fan speed automatically. You can
set fan speed only by the remote controller on
COOL and FAN modes.
2
UP(
) and DOWN(
) button
Used to adjust (increasing/decreasing)
O
O
O
temperature settings in 1
C/2
F(or 1
F) increments
O
O
O
O
in a range of 17
C/62
F to 30
C/88
F (or 86
NOTE: The control is capable of displaying
temperature in degrees Fahrenheit or degrees
Celsius. To convert from one to the other, press
and hold the Up and Down buttons at the same
time, for 3 seconds.
3
ON-OFF button
Power switch on/off.
LED Display
4
Shows the set temperature while on cool mode.
While on DRY and FAN modes, it shows the room
temperature.
Error codes:
E1- Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E2- Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E4- Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call for service.
Protection codes:
P1- Bottom tray is full - Connect the
drain hose and drain the collected
water away. If error repeats, call
for service.
OPERATING INSTRUCTIONS
Operating Instructions
COOL operation
-
Press the "MODE" button until the "COOL"
indicator light comes on. The unit will operate
the auto fan speed automatically.
-
Press the ADJUST buttons "▲" or "
select your desired room temperature. The
temperature can be set within a range of
O
O
O
O
O
17
C-30
C/62
F-88
F(or 86
F).
-
Press the "FAN" button on the remote
controller to choose the fan speed.
DRY operation
-
Press the "MODE" button until the "DRY"
indicator light comes on.
O
F).
-
Under this mode, you cannot select a fan
speed or adjust the temperature.
-
Keep windows and doors closed for the best
dehumidifying effect.
-
Do not put the duct to window.
FAN operation
-
Press the "MODE" button until the "FAN "
indicator light comes on. The unit will operate
the auto fan speed automatically. The
temperature cannot be adjusted on fan mode.
-
Press the "FAN" button on the remote
controller to choose the fan speed.
-
Do not put the duct to window.
SLEEP operation
This feature can be activated from the
remote control ONLY.
To activate SLEEP feature, the set temperature
O
O
O
will increase by 1
C/2
F(or 1
F) in 30 minutes.
The set temperature will then increase by
O
O
O
another 1
C/2
F(or 1
F) after an additional 30
minutes. This new temperature will be maintained
for 7 hours before it returns to the originally
selected temperature. This ends the Sleep mode
and the unit will continue to operate as originally
programmed.
NOTE: This feature is unavailable under FAN or
DRY mode.
7
" to