"Check Ambient Temperature on" means that the outside
temperature is measured before welding, "off," that it
is not; if the temperature is below 0°C (32°F), welding
should be performed only after taking appropriate pre-
cautions (heating, tent, for instance).
"Manual Input on" means that the manual input of welding
parameters or computed parameters is possible, "off,"
that the manual input is not allowed.
"Weld Pipe Segments on" means that at parameter input
before welding, either a straight-pipe joint or a joint of
pipe segments at an angle or tees etc. can be selected,
"off," that this selection is impossible, hence that on-
ly straight pipe-to-pipe welding operations can be per-
formed.
"Automatic Heating Element on" means that if an automat-
ically removing ("jumping") heating element is used,
the system will remove it automatically from in-between
the components during change-over, "off," that no au-
tomatic removal is controlled by the system even when
an automatically removing heating element is used; the
welder will have to remove it manually at change-over.
"Check Code Expiry on" means that the welder identifica-
tion code has to be current and not expired (default pe-
riod of validity 2 years from code issuance), or the weld-
ing operation cannot be started, "off," that the validity
of the code is not checked at all.
"Welder Code Options – M – " means that by pressing the
MENU key, the user can access a sub-menu that allows
determining when the welder code, if it is enabled un-
der "Recording," has to be entered: always, i. e. before
evey single welding operation, only before the first
welding operation after switching the unit on or only
before the first welding operation of a new day/date.
"Language – M – " means that by pressing the MENU key,
the user can access a sub-menu for selecting the display
and report language (see Sect. 4.1.3).
"Date/Time – M – " means that by pressing the MENU key,
the user can access a sub-menu for setting the clock (see
Sect. 4.1.4).
"Buzzer Volume – M – " means that by pressing the MENU
key, the user can access a sub-menu for setting the vol-
ume of the status buzzer (see Sect. 4.1.5).
"Temperature Unit – M – " means that by pressing the
MENU key, the user can access a sub-menu for selecting
centigrade or Fahrenheit as the unit for the tempera-
ture.
"Pressure Unit – M – " means that by pressing the MENU
key, the user can access a sub-menu for selecting bars or
pounds per square inch (psi) as the unit for the pressure.
"Length Unit – M – " means that by pressing the MENU key,
the user can access a sub-menu for selecting millimeters
or inches as the unit for the length.
16
EN
HÜRNER CNC ECO 1200 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Version October 2021