Appliance
Suction hose diameter (rotary
connector at nozzle end;
connector at vacuum cleaner
end)
Air temperature
en
Automatic filter cleaning (can
be disabled) approx. every
Charging station
Output power
Output voltage
Control
Cooling
Battery
NOTE
Battery charging times are extended if temperatures are too high or too low. Cold temperatures
may result in the battery not being fully charged.
Voltage
14.4 V
14.4 V
21.6 V
21.6 V
21.6 V
36 V
36 V
36 V
Battery
Rated voltage
Capacity
Energy capacity
Weight
Type of cell
Temperature monitoring
Deep discharge prevention
32
All manuals and user guides at all-guides.com
VC 20‑U‑Y/ VC 20‑UM‑Y
36 mm
-10...+40°C
15 s
Type
B 14/1.6 Li‑Ion
B 14/3.3 Li‑Ion
B 22/1.6 Li‑Ion
B 22/2.6 Li‑Ion
B 22/3.3 Li‑Ion
B 36/3.0 Li‑Ion
B 36/3.9 Li‑Ion
B 36/6.0 Li‑Ion
VC 40‑U‑Y/ VC 40‑UM‑Y
36 mm
-10...+40°C
15 s
365 W
7.2...36 V
Electronic charging control (microcontroller)
Active cooling
Li-ion
Charging time
21 min
23 min
21 min
24 min
31 min
24 min
44 min
42 min
B 36/6.0 Li‑Ion
36 V
6 Ah
216 Wh
1.8 kg
Li‑ion
NTC
Yes
For power tools
(examples):
SFC 14‑A
SFC 14‑A
SFC 22‑A
SFH 22-A
SFC 22‑A
TE 6‑A36
TE 7‑A
TE 30‑A