Sentiotec RS485 Instructions De Montage Et Mode D'emploi page 19

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation instructions, only for experts
Commands (CMD)
Func­
tion
CMD
Evapo-
set
rator
set
get
get
Light
set
set
get
get
Fan
set
set
get
get
Auxiliary
set
output
set
get
get
Preset
get
time
get
set
set
Param­
Status Value
eter
steam
on/off
steam
val
steam
steam
val
light
on/off
light
val
light
light
val
fan
on/off
fan
val
fan
fan
val
i-switch
on/off
i-switch
val
i-switch
i-switch
val
timer
on/off
timer
val
timer
timer
val
Switches the evaporator on/off
0-100
Sets a selected value between 0 and
100% as the preset humidity
Queries the evaporator status (on/off)
Queries the preset humidity
Switches the light on/off
0-100
Sets a selected value between 0 and
100% as the light power
Queries the light status (on/off)
Queries the preset light power
Switches the light on/off
0-100
Sets a selected value between 0 and
100% as the fan power
Queries the fan status (on/off)
Queries the preset fan power
Switches the auxiliary output on/off
0-7
Sets a selected value between 1 and
7 as the auxiliary output power
Queries the auxiliary output status
(on/off)
Queries the preset auxiliary output
power
Switches the timer for the preset time
on/off
5-1440 Sets a selected value between 5 and
1440 minutes for the timer for the pre-
set time
Queries the status of the timer for the
preset time (on/off)
Queries the remaining preset time in
minutes
p. 7/12
Description
EN

Publicité

Table des Matières
loading

Table des Matières