Installation instructions, only for experts

3. Functional scope

The following list includes all queries and settings allowed by the RS485 interface.
The actual functional scope depends on the sauna control unit used, the type
of devices connected to the sauna control unit and the sensor operating mode.
(R/W) Value can be set and queried (= read/write)
(R)
Value can only be queried (= read)
Possible settings and queries:
● Status (on/off) (R/W)
– Sauna
– Evaporator/humidity
– Light
– Fan
– Additional output
– Timer for preset time
– User program function
● Configured preset values (R/W)
– Sauna
– Humidity
● Sensor values (R)
– Heater sensor temperature
– Bench sensor temperature
– Actual humidity
– Foil sensor temperature
● Power level set (only with activated dimming) (R/W)
– Light
– Fan
– Auxiliary output
● Preset time (R/W)
● Operating time (R/W)
● Post-drying programme (R/W)
● User program setting (R)
● Function selector switch setting (R)
● Software version (R)
● Type of sauna control unit (Pro-B2, Pro-B3, ...) (R)
● General status (R)
p. 5/12