22.

WATER INLET

WATER INLET AND ELECTRONIC LEVEL CONTROL
For the initial filling of the boiler; as soon as the water comes into contact with the safety sensor (3), the
immersion heater automatically heats up.
If, during use, the water falls below this level (3), the machine automatically switches to standby mode.
As soon as the water falls below the automatic level sensor (2), the electronic controller (5) commands
the solenoid valve (4) to allow the refill of the boiler (1).
A non-return valve (6), stops pressurized water from returning up the water supply pipe, if the water
supply is cut off.
SACOME, Document CONFIDENTIEL,
SACOME, CONFIDENTIAL Document,
1
Chaudière
2
Sonde de Niveau
3
Sonde de Sécurité
4
Electrovanne
5
Centrale Electronique
6
Clapet Anti Retour
Edition 07/2008 - XEOS EVOLUTION 2 - XEOS TALL CUP
NOTES TECHNIQUES - TECHNICAL DOCUMENTS - page 33
it is forbidden to duplicate or communicate this document without previous authorization.
Boiler
Automatic Level Sensor
Safety Sensor
Solenoid Valve
Electronic Controller
Non Return Valve