iNSPEct tHE SHiPMENt
The high pressure booster pump has been carefully
inspected and packaged to assure safe delivery.
Inspect the pump and fittings and report to the carrier
any items which are damaged or missing.
iNStallatiON
The pump is designed to boost city water pressure or
water pressure from a private water system. Use this
high pressure stream to wash down milk parlors, barns,
garages and driveways, or for fire protection.
The pump is portable with a convenient carrying
handle. If an existing pressure water system is to
be used as a water supply, it can be connected with
available fittings and 1" or 1-1/4" high pressure hose
to the pump inlet. A special heavy duty 1" or 1-1/4"
suction hose with fittings is available as an accessory.
If the pump is permanently mounted on wall, use a 1"
or 1-1/4" pipe or heavy-duty hose for the suction line.
20 GPM models require a 1-1/4" discharge hose to
reduce friction losses.
limited Warranty
BERKELEY warrants to the original consumer purchaser ("Purchaser" or "You") of the products listed below, that they will be free from defects in material
and workmanship for the Warranty Period shown below.
Product
Water Systems:
Water Systems Products — jet pumps, small centrifugal pumps, submersible pumps and related
accessories
Pro-Source™ Composite Tanks
Pro-Source™ Steel Pressure Tanks
Pro-Source™ Epoxy-Lined Tanks
Sump/Sewage/Effluent Products
agricultural/commercial:
Centrifugals – close-coupled motor drive, frame mount, SAE mount, engine drive, VMS, SSCX,
SSHM, solids handling, submersible solids handling
Submersible Turbines, 6" diameter and larger
Our limited warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or
improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the
warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended
size or the warranty is void.
Your only remedy, and BERKELEY's only duty, is that BERKELEY repair or replace defective products (at BERKELEY's choice). You must pay all labor
and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered.
No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.
BERKELEY SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING
BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED
WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the
above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from
state to state.
This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011.
in the U.S.: BErKElEy, 293 Wright St., Delavan, Wi 53115
in canada: 269 trillium Dr., Kitchener, Ontario N2G 4W5
taBlE i - DiScHarGE PrESSUrE
No. of
GPM
HP
Stages
7
1/2
9
7
3/4
12
7
1
16
10
1/2
6
10
3/4
8
10
1
10
10
1
11
10
1-1/2
14
10
2
16
20
1
7
20
1-1/2
9
20
2
11
20
3
15
30
1
5
30
1-1/2
6
30
2
7
30
3
11
*for total discharge pressure, add this pressure to suction
pipe pressure. For example, an MGP7C pump taking suction from
a 100 psi water service line will produce 130 + 100 = 230 psi total
discharge pressure at 0 GPM flow. If suction pressure drops to 50
psi, discharge pressure will drop to 180 psi.
Warranty Period
whichever occurs first:
12 months from date of original installation, or
18 months from date of manufacture
5 years from date of original installation
5 years from date of original installation
3 years from date of original installation
12 months from date of original installation, or
18 months from date of manufacture
12 months from date of original installation, or
24 months from date of manufacture
12 months from date of original installation, or
24 months from date of manufacture
3
Discharge
Discharge
Pressure PSi
Pressure PSi
at rated flow
at No flow
90
130
123
173
162
229
74
113
97
147
134
188
146
202
173
206
197
260
75
110
97
143
123
175
195
250
59
75
71
91
81
106
129
167