G (Ground)
NOTICE: All the connectors marked G or GND are common.
i
Connect the ground side of the alarm input and/or alarm output to the G (Ground)
connector.
AO (Alarm Output)
The dome camera can activate external devices such as buzzers or lights. Connect the
device to the AO (Alarm Output) and G (Ground) connectors.
Connecting to the RS485
The camera can be controlled remotely by an external device or control system, such as a
control keyboard, using RS485 half-duplex serial communications signals.
Connecting the Power
Connect power of 12VDC or 24VAC for the camera.
When using a 12VDC adapter, connect the positive (+) pole to the '+' position and the
negative (-) pole to the '-' position.
Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certified/Listed Class 2 power source
only.
CAUTION:
Network Connection & IP assignment
The eneo scanning device tool is used to locate all eneo network cameras in a local net-
work. The tool does not need to be installed with a setup program. The program exe-file
can be started directly from the CD with a simple double click to use the program.
• Be careful not to reverse the polarity when you connect
the power cable.
• You can also use a router featuring PoE (Power over Ether-
net) to supply power to the camera.