Day-To-Day Operation; Description Display Symbols; The Machine - La Cimbali M39 DT Utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
WITH THE TIMER FUNCTION ON
With machines using just electrical heating
Turning the machine ON and OFF takes place automatically
as programed.
With machines using mixed gas/electric heating:
The electrical ON/OFF function does not control gas heating.
Therefore, at the end of each day's operating period, you must
TURN OFF the gas by turning the gas-tap knob back to the l
position. The following working day, turn the gas system back
ON as described in the "Gas Light-Up"paragraph.
N.B. When the machine is working in the automatic on/off
function do not use the general switch (14) to switch off the
machine. If this happens, the machine will not be able to
switch on again automatically.
WITH THE TIMER FUNCTION OFF
After switching on the machine using the on/off switch (14), the
message "PLEASE WAIT" appears on the display. Afterwards,
the menu below appears:
23 April
wednesday

Description display symbols

This symbol indicates the boiler water level.
During the loading phase, the dark bottom part of
the icon blinks.
When the optimum level is reached, the symbol looks like
this:
This symbol (dark inside) indicates that the
resistance is activated and functioning.
When the boiler pressure reaches the set value, the icon
looks like this
When the machine is in operation, the two icons
alternate on the display, indicating the presence of the electric
heating.
Note:
the customer cannot switch on or switch off the
electric heating.
When the on/off function is programmed, the electric heating
takes place automatically.

7. Day-to-day operation

2008
15:15:04
(light inside).
USE
C
This symbol indicates the boiler pressure value.
If the RES (24) key is pressed for about 3", the pressure
gauge will be displayed analogically. This will be shown
on the display:
23 APR 08
This symbol indicates that the machine is pre-heating
or the boiler pressure has dropped below 0.5 bar.
If one of the STOP/continuous coffee" (C) keys is
pressed, coffee will be served at the temperature reached at
that moment.
All of the other keys are disabled because the working pressure
has not been reached. If they are pressed, this menu appears
on the display
23 April
wednesday
While waiting for the machine to be ready for use, insert the
filter holders in the units.
The machine has reached the set work pressure and
temperature when the icon
Press a coffee selection key for each keypad to adjust the
temperature between the group and filter holder.
This symbol indicates that a services card has
been inserted in the slot (39) and, therefore, the
technical programming menu can be accessed.
41
RES 24
39
15:15
2008
15:15:04
disappears from the display.

Publicité

Table des Matières
loading

Table des Matières