Les langues disponibles

B
Gastype
B (min. -
A1 (min. -
max.)
max.)
Nat. gas
1 - 3 m
1 - 10 m
LPG
1,5 - 3 m
1 - 10 m
(A1 + A2 : B) : 1
Proportion vertical: horizontal (or 45
is always at least 2 : 1
all dimensions are exclusive the length of the roof outlet

Wall outlet

Always allow one metre vertical before passing through the outer wall.
The maximum length for a horizontal segment is 3 metres.
Determine the location of the appliance and the exterior wall duct.
Make an opening of Ø 160 mm for the wall duct.
Connect the wall duct vertically with a curve to the mouth of the appliance, push them rmly together and
place the clip binding. The blue rubber ring ensures su cient sealing of the outlet of the ue gas system.
If the appliance is placed more than 1 meter from the outside wall, place the rst meter on top the appliance,
then the elbow followed by the wall outlet. Finally make sure the construction is gastight.

Roof outlet

The roof outlet may pass through any point of the roof, with a bend to the ridge, if so desired. The roof outlet
is supplied with a universally adjustable plate for a sloped roof, or with an adhesive plate for a at roof.
Determine the location of the hearth and the roof outlet.
Make an opening of Ø 160 mm.
Connect the pipes vertically to the outlet of the hearth, press it in place and secure it with the clip.
Determine the length of the pipes you need, and ensure that the adhesive strip or the universal tile is properly
linked up with the roof.
Saw the outer pipe o to measure and link the roof outlet to the concentric pipes.

Placing the pipe system rst and then placing the hearth

You can also place the concentric pipe system before placing the appliance. In such case, ensure that you
make the connection with the appliance with an extendable pipe.