Switching from ºC/24-hour to ºF/12-hour indication
Press the OFF button  and the small ame button  simultaneously (2 sec) to switch from ºF (and the 12-
hour indication) to the ºC (and the 24-hour indication), and vice versa.

Possible settings

By pressing the SET button  you can switch quickly between MAN  day temperature  lamp  ventilator
 night temperature  timer  MAN.
MAN: this setting allows you to turn the ames manually higher or lower with the big- ame button  or the
small- ame button .
Day temperature (): this mode allows you to set the desired daytime temperature; the remote control set
will function as a thermostat.
Night temperature (): this mode allows you to set the desired night temperature.
TIMER: this mode allows you to preset 2 switch-on and 2 switch-o times per 24 hours. If the night setting is
on - - -, the stove will burn on the pilot ame.

Setting the temperature

Select the day temperature or night temperature by brie y pressing SET button .
Now press SET button  longer until the display starts ashing.
Preset the temperature with buttons  or  (5 ºC is the minimum day temperature).
Wait or press OFF button  to switch back to the thermostat-controlled system.
In order to save the batteries you are advised to reset the night-temperature until the display shows the '- - -'
signal.

Setting the timer function

Select the timer function by brie y pressing SET button  a few times.
Now press the SET button  longer until P1 () starts ashing.
Set the hours with button  and the minutes with button .
Brie y press SET button  for the next timing.
Once all 4 timings have been set, press OFF button  to end the presetting.

Operation (remote control)

Igniting the re

Open the gas turncock that is xed in the gas pipe leading to the stove.
Press "O I" switch  on the gas control block in the "I" position.
Turn control button  on the gas control block to the ON position.
Simultaneously press buttons  and  on the handset. A short acoustic
signal indicates the start, and is followed by short acoustic signals (0.2
sec/signal, 1Hz.) until the pilot ame and the chief burner are ignited.
After the main burner has lit, the ame height will automatically go to
the maximum position.

Possible error messages

Long signals (0.8 sec. signal with 0.2 sec. interval) during lighting : batteries of the receiver are almost
empty. (After hearing this signal, you can switch on the appliance for about another 10 times.)
5 seconds continuous signal : error message. One of the cables may not be connected, or the "O I" switch
is not in the "I" position.
5 short signals (0.2 sec. signal with 0.2 sec. interval) : ignition of the pilot ame and the main burner has
failed. Possible cause: air in the pilot burner pipe.
Important: If the pilot ame has gone out you must wait at least 5 MINUTES before repeating the
!
above-mentioned steps.