Then, if a temperature probe is connected, the clock is switching to the option for selecting the
alternative display of time and temperature, otherwise this last press enables to escape from
"Setting the time" menu after running the self test :
1) Switching on all the Leds for 2 seconds,
2) Switching off all the Leds for 1 second,
3) Return to normal display.
Alternative display menu for time and temperature :
After selecting the option, press "Select" key to confirm, the temperature adjusting menu
displays :
Press "+" key to adjust the displayed temperature by adding up to +9°C or decreasing up to
-9°C.
This adjustment enables to calibrate the displayed temperature according to the official
temperature.
Once the adjustment is over, press "Select" key to confirm.
This last press enables to escape from "Setting the time" menu after running the self-test :
1) Switching on all the Leds for 2 seconds,
2) Switching off all the Leds for 1 second,
3) Return to normal display.
9.3. Reset DHF clock to "Initialisation" mode
On leaving the factory, the DHF clock is set in "Initialisation" mode.
However, it can be necessary to set it again in this mode.
Press the "+" key for 3 seconds to enter in the TEST menu.
The TEST menu displays :
From this TEST menu, press the "Select" key for 6 seconds.
22
Alternate display time/temperature :
Press "+" key
Display of temperature only
- the construction of the time message as and when the data arrive,
if the time signal is not received only the colon (:) is displayed
- The clock displays 0:00 for 5 seconds then display disappears. The clock is
now reset to "Initialisation" mode. Press "+" key to exit this menu.