Installation Instructions - Monogram ZGP484NG Instructions D'installation

Masquer les pouces Voir aussi pour ZGP484NG:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
Instructions
WARNING:
be performed by a qualified installer or gas supplier
in accordance with the manufacturer's instructions
and all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified
agency performing this work assumes responsibility
for the conversion.
WARNING:
the factory, is set for use with its intended gas. If you
wish to use your rangetop with the alternate gas, you
must first replace the orifices and convert the pressure
regulator.
WARNING:
must be made before turning on the burner. Failure to
do so could result in serious injury. Be sure pressure
regulator has been converted as described in Step 2.
TOOLS YOU NEEDED FOR CONVERSION
Safety Glasses
Crescent Wrench
1/2" Deepwell
Socket Wrench
1/4" and 7mm
Nutdrivers
1 ORIFICE HOLDER
The range orifice holder is located behind the front access
panel at the bottom of the range. Remove the door(s)
(See instructions on page 10)
and the screws on the top and
bottom of the front access
panel. Remove the front
access panel to access the
orifice holder.
Additional orifices may be
present. Use only the orifices
specified in the instructions for
your range or rangetop.
22
Convert Natural Gas to LP Gas Operation
Convert LP Gas to Natural Gas Operation
This conversion must
The rangetop, as shipped from
The following adjustments
7/16" (11 mm) Open
End Wrench
Small Flat-Head Screwdriver
(2 to 2.4 mm or 3/32" tip size,
60 mm long)
Philips
Small Pliers
Screwdriver
Front Access Cover
2 CONVERT THE REGULATOR(S)
Disconnect all electrical power at the main circuit
breaker or fuse box.
A. Shut off the gas supply by closing the manual
shut-off valve on the unit or by the wall.
B. Move the range out in order to access the rear of
the unit.
C. Remove the range back to access the regulator(s) -
(1) on 30" & 36" ranges and (2) on 48" ranges.
D. Convert the pressure regulator(s):
• Unscrew the cap with plunger.
• Place your thumb against flat side of the plunger
and press down to snap the plunger out of the cap.
• Carefully look at the plunger to locate the NAT
or LP position.
• Turn the plunger over so that the desired gas is
showing
near the
bottom.
• Snap the
plunger
back into
the cap.
NAT.
Position
• Screw the
cap back
onto the
regulator.
E. Reverse these steps to reassemble the pressure
regulator.
3 CHANGE BURNER ORIFICES
INSTALLATION TIP: First remove all
orifices and then start replacing them.
This will help to prevent the possibility
that some may not be replaced.
A. Remove the burner grates,
burner caps and burner heads.
B. Loosen the top burner
orifices using a 7 mm
nut driver. Use small
pliers to carefully lift out the orifices.
The main orifice is located
low in the center of the
burner, while the simmer
orifice is located higher
beside the center of the
burner.
Main
Orifice
Gasket
Cap
NAT
LP
Plunger
LP
NAT
LP Position
Pressure Regulator
Burner Cap
Burner
Head
Spark
Igniter
Burner Base
Simmer
Orifice
31-10755-4

Publicité

Table des Matières
loading

Table des Matières