STEP 3
INSTALL ANTI-TIP DEVICE
To reduce the risk of tipping the range, the range must
be secured by a properly installed anti-tip bracket. See
installation instructions shipped with the bracket
for complete details before attempting to install.
To check if the bracket is installed and engaged properly,
look underneath the range. The anti-tip bracket should
be inserted into the opening on the anti-tip brace on the
range. If the bracket arm misses the brace to the left or
right, or the bracket arm is not protruding through the
brace opening, the bracket must be reinstalled.
If the range is pulled from the wall for any reason, always
repeat this procedure to verify the range is properly
secured by the anti-tip bracket.
If your range has no anti-tip bracket, call 1.800.626.8774
to receive one at no cost.
If the anti-tip device supplied with the range does not fit this
application, use the universal Anti-Tip Device WB2X7909.
Read the AHAM Anti-Tip Safety Brochure packed with
the bracket.
Anti-Tip Parts Provided
4 Wood Screws
3 Hex Head Screws
(2 required, 1 extra)
Anti-Tip Brace
12
Installation
A child or adult can tip the range and be killed.
Verify the anti-tip bracket has been properly installed
and engaged.
Ensure the anti-tip bracket is re-engaged when the range
is moved.
Do not operate the range without the anti-tip bracket in
place and engaged.
Failure to follow these instructions can result in death or
serious burns to children or adults.
Anti-Tip Bracket
AHAM Anti-Tip
Safety Brochure
WARNING
Tip-Over Hazard
• Attach the anti-tip brace onto the bottom of the
range in the recessed area. Install 2 hex screws
(provided) through the brace and into the range.
NOTE: This anti-tip device may be installed on the
opposite side of the range.
Alternate Brace
Position
• Measure and mark Dimension A (see table below)
from the left (or right) side of the installation
location. If the countertop has an overhang,
add that dimension to Dimension A.
• Place the anti-tip bracket against the floor and
back wall at the marked location. Mark screw holes
for fastening the bracket to the wall sole plate and
the floor.
• Drill 1/8" pilot holes at a 20° angle.
• Secure the bracket to the wall and/or floor with
at least 2 wood screws (provided).
For Concrete or Cement Construction: You must
use appropriate fastening hardware (not provided).
Range
A
30"
5-1/16"
36"
5-1/16"
48"
8-1/4"
Hex Screws
Anti-Tip Brace
Anti-Tip Bracket
Wall Sole Plate