Monogram ZGP484NG Instructions D'installation page 26

Masquer les pouces Voir aussi pour ZGP484NG:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions for Gas Conversion
ADJUST BURNER FLAMES
8
Normally, burners do not need further adjustment.
Make adjustments only when necessary.
A. Turn on the gas. Plug in electrical cord.
B. Turn all burners on highest setting and check
the flames. They should be blue in color. When
using LP gas, the flames may have some yellow
tipping at the ends of the flame. Foreign particles
in the gas line may cause an orange flame at first,
but this will soon disappear.
C. Turn the burner knob to "LO" while observing the
flame.
Adjust the setting of the upper row of flames using
the valve bypass screw as follows:
Adjustments must be made with two other burners
in operation on a medium setting. This prevents the
upper row of flames from being set too low, resulting
in the flame being extinguished when other burners
are turned on.
D. To adjust the flame, remove the knobs. Insert a small
flat-blade screwdriver into the hole in the center of
the valve stem to engage screw.
NG (Natural) Gas, 5" W.C.P.
MODEL
BURNER
ZGP48
ALL SURF. Main
ZGP36
BURNERS Simmer
Main
ZGP304 RF BURNER
Simmer
Main
ZGP304 RR, LR, LF
Simmer
ALL
GRILL
ALL
GRIDDLE
ZGP48/
BAKE MAIN
ZGP36
ZGP30
BAKE MAIN
ZGP48
BAKE COMPANION
ALL
BROIL MAIN
ZGP48
BROIL COMPANION
Once the conversion is complete and checked, fill out the conversion label and affix the label near the rating label. For ranges,
place the label beneath the control panel. For rangetops, place the label on the bottom of the unit.
26
BURNER OUTPUT RATINGS: BTU/HR
BTU
ORIFICE SIZE
RATE
16,800 0.075" (1.90mm) 190XN
1,200 0.002" (0.51mm)
51SL
16,800 0.075" (1.90mm) 190XN
1,200 0.002" (0.51mm)
51SN
8,800 0.050" (1.26mm) 126HXN
1,200 0.002" (0.51mm)
51SN
15,000 0.0689" (1.75mm)
0.069
18,000 0.076" (1.93mm)
0.076
0.0886"
24,500
0.089
(2.25mm)
23,500 0.0866" (2.20mm)
0.087
10,500 0.0531" (1.35mm)
0.053
12,500 0.063" (1.60mm)
160
9,000 0.052" (1.32mm)
132
• If the flames are too small or flutter,
turn the screw counterclockwise.
• If the flames are too large, turn the screw
clockwise.
E. Make the adjustment by slowly turning the screw
until flame appearance is correct.
LP (Propane) Gas, 10" W.C.P.
ID
MODEL
BURNER
ZGP48
ALL SURF. Main
ZGP36
BURNERS Simmer
ZGP304 RF BURNER
ZGP304 RR, LR, LF
ALL
GRILL
ALL
GRIDDLE
ZGP48/
BAKE MAIN
ZGP36
ZGP30
BAKE MAIN
ZGP48
BAKE COMPANION
ALL
BROIL MAIN
ZGP48
BROIL COMPANION
BTU
ORIFICE SIZE
RATE
13,800 0.043" (1.08mm)
1,200 0.013" (0.34mm)
Main
13,800 0.043" (1.08mm)
Simmer
1,200 0.013" (0.34mm)
Main
7,900 0.033" (0.84mm)
Simmer
1,200 0.013" (0.34mm)
14,000 0.047" (1.19mm)
16,000 0.047" (1.19mm)
0.0571"
23,000
(1.35mm)
21,500 0.0531" (1.35mm)
10,000 0.0374" (0.95mm)
11,500 0.041" (1.04mm)
9,000 0.0360" (0.91mm)
ID
108XL
34SL
108XL
34SL
84XL
34SL
0.047
0.047
0.055
0.053
0.037
104
91
31-10755-4