Connecting The Bus Coupler As A Final Statio; Connecting The Bus Coupler Logic And Load Supply - Aventics PROFIBUS DP Mode D'emploi

Coupleur de bus pour bdc, design b
Masquer les pouces Voir aussi pour PROFIBUS DP:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 93
66
AVENTICS | PROFIBUS DP | R412009414-BDL-001-AE
Assembly
1
X71
X72
2
X10
PO WE R
X10
2
1
3
4
6.3.3

Connecting the bus coupler as a final statio

1. Set up the correct pin assignment (see Tab. 5 on page 65)
on the plug connections if you do not use pre-assembled
wiring.
2. Connect the incoming bus connection to X71 (1).
3. Cover the X72 (BUS OUT) socket with a PROFIBUS
terminator plug (see chapter "Spare parts and accessories"
on page 89).
4. Connect the shield on both sides of the bus cable directly to
the plug housing (EMC housing) if non-pre-assembled
cables and plugs with metal housing are used. This protects
data lines from terminal interferences.
Ensure that the plug housing is securely fitted to the bus
coupler housing.
6.3.4
Connecting the bus coupler logic
and load supply
Power is supplied to the valves and the bus coupler via the X10
(POWER)
plug.
When connecting the logic and load supply of the bus coupler,
ensure pin assignment according to Tab. 6.
Tab. 6:
Assignment of the X10 (POWER) plug, M12, A-coded
Pin
X10
Assignment
1
U
Power supply for the bus coupler logic
L
2
U
First valve power supply
Q1
3
OV
Ground for U
4
U
Second valve power supply
Q2
1)
Both supply voltages (pin 2, pin 4) must be protected by an external fuse (3A, F).
W
U
, U
and U
L
Q1
Q2
W
With the U
and U
Q1
switched off byte by byte (each byte represents 4 double
solenoid or 8 single solenoid valves).
U
and U
Q1
L
,
are galvanically connected to one another.
valve supplies, the valves can be
Q2
1)
Q2
1)