INSTALLATION INSTRUCTIONS
Gas information
G25/25
mbar
Burner-
(kW)
type
Simmer
1.00
Semi-
2.00
rapid
Rapid
3.00
Wok
4.50
EN 32
G20/20
G25/20
G30/29
mbar
mbar
mbar
(kW)
(kW)
(kW /
g/h)
1.00
0.90
0.90 / 65
2.00
1.80
1.60 /
115
3.00
2.70
2.30 /
166
4.50
4.50
3.50 /
252
Setting up the appliance for other gas
This appliance has been set up for natural gas (G25/25 or G20/20).
The appliance can be set up for other gas types and pressures by
means of a conversion kit. You can order the kit from the sales and
service organisation. The conversion instructions are supplied with
the kit.
G31/29
G31/36
G30/50
mbar
mbar
mbar
(kW /
(kW /
(kW /
g/h)
g/h)
0.79 / 57
0.90 / 65
1.00 / 72
1.41 /
1.60 /
2.00 /
101
115
2.02 /
2.30 /
2.70 /
146
166
3.08 /
3.50 /
4.00 /
222
252
G31/50
G31/67
mbar
mbar
(kW /
(kW /
g/h)
g/h)
g/h)
0.88 / 63
1.00 / 72
1.76 /
2.00 /
144
127
144
2.38 /
2.70 /
194
171
194
3.52 /
4.00 /
288
253
288