In environments with risk of sub-zero tempera-
tures, a glycol/water mixture can be used with
40/60 mixture (glycol/water), with a recom-
mended minimum environment temperature of
-20 °C.
The lower the cooling water input temperature,
the better the cooling of the motor.
For some cases a higher input temperature can
be allowed when requested and checked by the
manufacturer.
Motor type
Number of
M3LP
inlets
Frame type
280 SM_
1
315 KH_
1
315 LK_
1
355 ML_
1
355 LK_
1
400 L_
1
450 L_
1
500 L_
1
Cooling
Water
Water
water flow
pressure
temp . rise
rate
min . (bar)
(K)
(l/min)
20
2,0
7-12
30
2,0
7-12
30
2,0
7-12
30
2,0
10-15
35
2,0
10-15
40
2,0
10-15
50
2,0
10-15
60
2,0
10-15
The outlet water temperature rise is from 7–15 K.
The minimum pressure and amount of cooling
water for the basic construction of a water
cooled motor is shown in the following table.
Please check the requirements for pressure and
the amount of cooling water in the case of spe-
cial constructions.
(If the amount of water varies, its temperature
rise will be inversely proportional to the flow rate.)
Heat transfer of thermal loss in
(approx .) ratio air/water at room
temperature
Temperature of inlet cooling water
25 °C
40 °C
10/90
30/70
10/90
30/70
10/90
30/70
10/90
30/70
10/90
30/70
10/90
30/70
10/90
30/70
10/90
30/70
7
Water-space
of st . frame
(l)
1,2
3,5
4,7
28
35
50
65
71