Charging of the battery may take several minutes after connecting the power to initiate, depending on the
battery's internal operating temperature. This is a normal condition and is intended for safe battery charging.
This circumstance is more likely when the battery has been fully discharged.
If the device power supply remains connected when the battery is fully charged, the four LEDs will turn off
NOTE
within approximately 1 hour.
For oxygen concentrators equipped with batteries:
The Oxygen Concentrator battery does not need to be fully discharged before recharging. It is
recommended to charge the Oxygen Concentrator battery after each use.
Lithium batteries may permanently lose capacity when exposed to extremely hot temperatures with the
batteries fully charged or completely depleted. For extended storage, it is recommended that batteries be
charged 25 to 50% and remain within a temperature range of 73°F ± 35°F (23°C ± 2°C).
The use of some oxygen administration accessories not specified for use with this oxygen concentrator may
impair its performance. Recommended accessories are referenced within this manual
To Equipment Provider: The following oxygen administration accessories are recommended for use with
NOTE
the Oxygen Concentrator:
•
tubing:
•
air intake filter:
•
Do not operate the Oxygen Concentrator without the air intake filter in place. If a second filter is provided,
insert the "replacement" filter before you clean the dirty filter. Clean the dirty filter in a warm soap and water
solution then dry thoroughly prior to use.
NOTE
The Manufacturer does not recommend the sterilization of this equipment.
To prevent a void warranty, follow all manufacturers' instructions.
Portable and mobile RF communications equipment can effect medical electrical equipment.
NOTE
There is never a danger of depleting the oxygen in a room when you use your Oxygen Concentrator unit.
AirSep offers the OxySafe as an optional accessory. This is intended to be used in conjunction with the
FreeStyle concentrator. For customers in regions requiring compliance to EN ISO 8359:1996-
Ammendment1:2012, this accessory will meet this need.
NOTE
The OxySafe is a thermal fuse to stop the flow of gas in the event that the downstream cannula or oxygen
tubing is ignited and burns to the OxySafe. It is placed in-line with the nasal cannula or oxygen tubing
between the patient and the oxygen outlet of the Visionaire.
For proper use of the OxySafe, always refer to the manufacturer's instructions (included with each
OxySafe kit).
AirSep offers an OxySafe kit that includes OxySafe with 2" of tubing to connect to the oxygen outlet;
PN 20629671
MN131-1 rev C
Nasal Cannula with 7 feet (2.1 m) of
Part No. CU002-1
Use only the manufacturer's replacement
Part No. FI144-1
OxySafe Kit
Part No. 20629671