Manually operated bilge pump
Typical applications
Bilge pump and macerator pump.
Design features
Pump body:
Shaft:
Screws:
Elastomers:
Handle:
Connection:
Diameter:
Height:
Max width:
Handle length:
Weight:
Model specification
Type
Viking Thrudeck
Viking Thrudeck
Viking Bulkhead
Viking Bulkhead
Viking Thrudeck
For installation behind vertical wall or
under deck with sealing boot, complete
with a coverplate.
Viking Bulkhead
For surface installation with horizontal
lever.
Both types
The mounting ring is provided with thread-
ed inserts for behind-wall or under-deck
installation and holes for surface installa-
tion.
The direction of flow through the pumps
is marked by an arrow on the housing and
Original instructions
PP
Stainless steel
AISI 316
Stainless steel
AISI 316
Nitrile
Anodised aluminium
1
/
" (38 mm) or
1
2
1" hose (25 mm)
164 mm
133 mm
253 mm
285 mm
2 kg
Part No
1
/
"
70-50005
1
2
1"
70-50025
1
/
"
70-50007
1
2
1"
70-50027
can be easily changed by removing the
eight screws which hold the pump body
and mounting ring together.
Capacity
At 1 m suction height: 0,9 l/stroke
Capacity at:
60 stroke/min
80 stroke/min
100 stroke/min
Max suction height: 4 m
Installation
Viking Thrudeck
When wall-mounting Thrudeck, note the
marking "UP" on the mounting ring. Be
sure that the pump is mounted with this
marking up.
For mounting see the hole layout, next
page. The dimensions are in inches and
mm. The outside edge of the large hole
should be rounded approx. 2 mm.
Four metric 6 mm fastening screws are
supplied.
Before installing Thrudeck put some
talcum powder in the hole of the sealing
boot and slip it over the neck
of the lever. Then hold the pump in posi-
tion behind the wall or under the deck
and pull the boot through the hole. Hold
the coverplate in place and install the
screws.
Viking Bulkhead
For mounting Bulkhead, use # 12
screws with pan head ("pozidrive").
> English
54 l/min
72 l/min
90 l/min
5