Replacing The Thermostat; Replacing The Heater - Sibir V110 Mode D'emploi

Réfrigérateur au kérosène/électricité
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

REPlAcINg thE thERmoStAt

1
Remove the plug from the wall socket.
2
Remove the capillary tube end at the cooling element
and pull it carefully out from the rear of the cabinet
3
Remove the plastic cover and the wires from the
thermostat.
4
Remove fastening screws or nuts and pull the
thermostat out.
5
Fit the new thermostat.
6
6
Connect the wires and replace the plastic cover.
7
Reattach the capillary tube.
8
Plug into the wall socket.

REPlAcINg thE hEAtER

1
Remove the plug from the wall socket.
2
Remove the terminal cover and loosen the heater
cables.
3
look for a small cover on the boiler case and
remove it.
4
lift the heater and take it out.
5
Insert the new heater into the heater tube.
6
Make sure that the glass wool is put back around
the heater and fit the cover again.
7
Connect the cables and fit the terminal cover in
reverse order.
8
Put the refrigerator on test.
www.sibir.com
6
!
be CAReFUl noT To bReAK THe CAPIllARy
TUbe!
Make sure that the capillary tube makes contact
with the cooling element only where it is to be
fastened.
Cover
Heater
Terminal box
18
copyright © sibir international

Publicité