tRoublEShootINg chARtS
ElEctRIcAl oPERAtIoN
A. REFRIgERAtoR Not coolINg At All
1
Cooling unit at the cabinet rear warm?
2
Ventilation around the cooling unit provided?
3
Is the refrigerator levelled?
4
Is the room temperature lower than 43°C?
5
Remove the kerosene tank. Run the refrigerator for two hours. Tilt the unit
slightly forwards (towards the front) until it reaches an angle of 15-25°.
Maintain this position for 60 seconds then return the refrigerator to a level
position again. open the freezer door. Put your hand against the rear wall
of the freezer compartment. Is it getting colder?
6
The refrigerator should now be operating normally.
b. REFRIgERAtoR Not coolINg At All
1
Is the supply cable plugged in?
2
does other equipment function in the
refrigerators wall socket?
3
Is the control knob in high figure position?
4
Check the thermostat and heater.
www.sibir.com
YES
YES
YES
YES
YES
YES
YES
YES
See "Troubleshooting charts > electric operation >
NO
b. Refrigerator not cooling at all".
Arrange for ventilation.
NO
level the refrigerator.
NO
Place the refrigerator in a colder place.
NO
NO
Plug into the wall socket.
NO
Check and if necessary replace the buildings
NO
electrical fuse. If neccessary call an electrician.
Turn the knob to highest figure position.
NO
Replace the cooling unit.
copyright © sibir international
25