8.4 Size 1 ACT4XX (0.55...1.5 kW, 400 V)
Type
ACT4XX
Size
Output, motor side
GB
Recommended motor shaft power
Output current
I Longt overload (60 s)
I Shortt overload (1 s)
Output, braking resistor
Min. braking resistance
Recommended braking resistor (U
= 770 V)
Input, mains side
Mains current
Fuses
Type UL 600 VAC RK5
Mechanical
Dimensions
Weight approx.
Connection terminals
Ambient conditions
Energy dissipation (2 kHz switching
frequency)
Output current (Maximum current in continuous operation)
Frequency inverter
nominal power
0.25 kW
0.37 kW
0.55 kW
0.75 kW
1.1 kW
1.5 kW
1)
1)
Connection requires a commutating choke.
2)
Mains current with relative mains impedance ≥ 1% (see chapter „Electrical
installation")
96
2)
2 kHz
1.0 A
1.6 A
1.8 A
2.4 A
3.2 A
3.8 A
3)
Reduction of switching frequency in thermal limit range
Quick Start Guide ACT
P
kW
I
A
I
A
I
A
R
Ω
dBC
R
Ω
I
A
I
A
I
A
HxWxD mm
m
kg
A
mm
2
P
W
Switching frequency
4 kHz
1.0 A
1.6 A
1.8 A
2.4 A
1)
3.2 A
1)
3.8 A
3)
-05
-07
-09
1
0.55
0.75
1.1
1.8
2.4
3.2
2.7
3.6
4.8
3.6
4.8
6.4
300
300
300
930
634
462
1.8
2.4
2.8
1)
6
6
190 x 60 x 175
1.2
0.2 ... 1.5
40
46
58
8 kHz
16 kHz
1.0 A
0.7 A
1.6 A
1.1 A
1.8 A
1.2 A
2.4 A
1.6 A
3.2 A
1)
2.2 A
3.8 A
3)
2.6 A
-11
1.5
3.8
3)
5.7
7.6
300
300
3.3
1)
68
3)
12/20