8.2 Size 2 ACT2XX (1.5...3.0 kW, 230 V)
Type
ACT2XX
Size
Output, motor side
GB
Recommended motor shaft power
Output current
I Longt overload (60 s)
I Shortt overload (1 s)
Output, braking resistor
Min. braking resistance
Recommended braking resistor
(U
= 385 V)
dBC
Input, mains side
Mains current
1ph/N/PE; 2ph
Mains voltage
Fuse 3ph
1ph/N; 2ph
UL type 250 VAC RK5, 3ph
1ph/N; 2ph
Mechanical
Dimensions
Weight approx.
Connection terminals
Ambient conditions
Energy dissipation (2 kHz switching
frequency)
Output current (Maximum current in continuous operation)
Frequency inverter
nominal power
1.5 kW
2.2 kW
3.0 kW
2) 4)
1)
Three-phase connection requires a commutating choke.
2)
One- and two-phase connection requires a commutating choke.
3)
Mains current with relative mains impedance ≥ 1% (see chapter „Electrical
installation")
connection
5)
94
3)
3ph
2 kHz
7.0 A
9.5 A
12.5 A
4)
Maximum output current = 9.5 A with single-phase and two-phase
Reduction of switching frequency in thermal limit range
Quick Start Guide ACT
-11
P
kW
I
A
I
A
I
A
R
Ω
37
R
Ω
75
7
I
A
13.2
U
V
10
I
A
16
10
I
A
15
HxWxD
mm
m
kg
A
mm
2
P
W
84
Switching frequency
4 kHz
7.0 A
2)
9.5 A
2)
1)
12.5 A
1) 5)
-13
2
1.5
2.2
7.0
9.5
12.5
10.5
14.3
14.0
19.0
37
55
9.5
10.5
16.5
2)
16.5
184 ... 264
16
20
15
20
250 x 60 x 175
1.6
0.2 ... 1.5
115
8 kHz
16 kHz
7.0 A
4.8 A
9.5 A
2)
6.5 A
12.5 A
1) 5)
8.5 A
-15
3.0
4)
4) 5)
16.2
19.0
37
37
1)
2) 4)
16
20
15
20
170
5)
12/20