Télécharger Imprimer la page

BONFIGLIOLI ACTIVE ACT201 Mode D'emploi page 95

Masquer les pouces Voir aussi pour ACTIVE ACT201:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

8.1 Size 1 ACT2XX (0.55...1.1 kW, 230 V)
Type
ACT2XX
Size
Output, motor side
Recommended motor shaft power
Output current
I Longt overload (60 s)
I Shortt overload (1 s)
Output, braking resistor
Min. braking resistance
Recommended braking resistor
(U
= 385 V)
dBC
Input, mains side
Mains current
3)
3ph
1ph/N/PE; 2ph
Mains voltage
Fuse 3ph
1ph/N; 2ph
UL type 250 VAC RK5, 3ph
1ph/N; 2ph
Mechanical
Dimensions
Weight approx.
Connection terminals
Ambient conditions
Energy dissipation (2 kHz switching
frequency)
Output current (Maximum current in continuous operation)
Frequency inverter
nominal power
0.55 kW
0.75 kW
1.1 kW
1)
Three-phase connection requires a commutating choke.
2)
One- and two-phase connection requires a commutating choke.
3)
Mains current with relative mains impedance ≥ 1% (see chapter „Electrical
installation")
4)
Maximum output current = 9.5 A with single-phase and two-phase
connection
5)
Reduction of switching frequency in thermal limit range
12/20
P
kW
I
A
I
A
I
A
R
Ω
R
Ω
I
A
U
V
I
A
I
A
HxWxD mm
m
kg
A
mm
2
P
W
Switching frequency
2 kHz
4 kHz
3.0 A
3.0 A
4.0 A
4.0 A
5.4 A
2)
5.4 A
2) 5)
Quick Start Guide ACT
-05
-07
1
0.55
0.75
3.0
4.0
4.5
6.0
6.0
8.0
100
100
230
160
3
4
5.4
7.2
184 ... 264
6
10
10
16
6
10
10
15
190 x 60 x 175
1.2
0.2 ... 1.5
43
53
8 kHz
3.0 A
4.0 A
5.4 A
2) 5)
-09
GB
1.1
5.4
5)
7.3
8.0
100
115
5.5
1)
9.5
73
16 kHz
2.0 A
2.7 A
3.7 A
5)
93

Publicité

loading

Ce manuel est également adapté pour:

Active act210Active act401Active act410