LIMIT SWITCH ADJUSTMENT
Operator equipped with AS2-eco come with the limit switch LSS-4.
(Limits for OPEN & CLOSE and SAFETY-Limit-Switch Open and Closed,
without additional limits)
1
2
3
4
5
6
1. Drive the door to wished CLOSED position.
2. Set the control cam 5 (white) the way that the limit switch is operated.
3. Tighten the fixing screw A.
4. Drive the door to wished OPEN position.
5. Set the control cam 2 (green) the way that the limit switch is operated.
6. Tighten the fixing screw A.
7. Fine adjustment is done with the screw B.
8. The safety limit switches 3 and 4 (red) must be set the way that they react directly after
passing the control limit switch.
9. After the operation test, control the fixing screw.
10. The additional limit switches 1 and 6 have change-over contact free of potential.
A
B
1. Additional Limit Switch OPEN
2. Limit Switch OPEN
3. Safety Limit Switch OPEN
4. Safety Limit Switch CLOSED
5. Limit Switch CLOSED
6. Additional Limit Switch CLOSED
8
Limit Switch - LSS6
green
green
red
white
white
Revision_11_2007
red