Before the installation of power cables and control devices it is essential to take note of all the
following specifications and warnings. If they are not heeded serious injuries or damage to the
drive can occur.
The control housing of the door drive may only be opened by trained"Chamberlain" specialist
personnel. If necessary please contact your local Chamberlain dealer.
Before electrical installation or the starting up of the drive please study the circuit diagram
carefully. The valid local regulations must be followed for all the electrical wiring work.
Before carrying out any maintenance work on the door drive it is first necessary to disconnect
the power supply / power transmission at the main switch.
After completion of the maintenance work the danger zone must be cleared and secured again
before restarting.
If you require additional accessories or spare parts
MATRIX FOR THE USE OF SAFETY EQUIPMENT
TYPE OF CONTROL
Control by continuous switch
operation
Pulse actuation within visual
range of door
Automatic control
l
A:
Pushbutton for control by holding down continuously
l
B:
Keyswitch, or suchlike for controlling by means of continuous actuation
l
C:
Limitation of driving force by force limiting (clutch) and protection devices
(safety edge padding).
l
D:
Device to detect people or obstacles which are on the ground on one side (inside) of the door
leaf (infrared light barrier)
l
E:
Device to detect people or obstacles which are on the ground on both sides
(inside and outside) of the door leaf (infrared light barrier).
ADVICE: For more detailed information see EN12453.
ELECTRICAL CONNECTION
please contact your local Chamberlain dealer.
CHAMBERLAIN - GmbH
Alfred-Nobel-Str. 4
66793 Saarwellingen
ORDERING FAX NO: (0049)(0)6838-907179
TECHNICAL HOTLINE: (0049)(0)6838-907222
Trained
people(inaccessible
to the public)
Group 1
A
C
C and D
DOOR WILL BE USED BY
Public area
Group 2
B
C and D
C and E
7
(General public area)
Group 3
No info.
C and E
C and E
Revision_11_2007