4. Specifi cation and ordering information
Signifi cance of the digits 1. to 9.
Order Code
1.
Version of the transmitter
Standard,
measuring output non intrinsically safe
EEx ia IIC T6, ATEX
measuring output intrinsically safe
2.
Mechanical angle range
Angle range, to 50°
Angle range > 50 to 350°
3.
Sense of rotation
Sense of rotation clockwise
Sense of rotation counter-clockwise
"V" characteristic
4.
Drive Shaft
Standard dia. 2 mm, length 6 mm
Special dia. 6 mm, length 6 mm
Special dia. 1/4", length 6 mm
Transformation 1:4, dia. 6 mm, length 15 mm
Transformation 1:1, dia. 6 mm, length 15 mm
Transformation 4:1, dia. 6 mm, length 15 mm
Transformation 32:1, dia. 6 mm, length 15 mm
Transformation 64:1, dia. 6 mm, length 15 mm
5.
Measuring range
Basic confi guration, programmed
0 to fi nal value, acc. to order
"V" characteristic, acc. to order
6.
Characteristic of output variable
Characteristic linear
Function X to the power of 1/2
Function X to the power of 3/2
Function X to the power of 5/2
Customized
7.
Test certifi cate
Without test certifi cate
Test certifi cate in German
Test certifi cate in English
8.
Marking the system zero position
System zero position not marked
System zero position marked
9.
Climatic rating
Standard climatic rating
Improved climatic rating

5. Technical data

Measuring input
Measuring range of
rotation angle:
Programmable between 0 to 10 and
0 to 50 or
0 to 50 and 0 to 350
14
Drive shaft diameters: 2 or 6 mm resp. 1/4"
Frictional torque:
711–
1
2
Sense of rotation of
the drive shaft:
1
Measuring output
2
Power supply:
0
1
2
0
Max. residual ripple:
1
2
Output variable I
A
B
External resistance:
C
D
E
0
Accuracy
9
Z
Reference value:
Basic accuracy:
0
1
Mechanical withstand
2
Permissible vibrations: Acc. to EN 60 068-2-6
3
Shock:
4
Permissible static
load on the shaft:
0
D
E
Mounting position:
Material
0
1
Field type housing:
0
Cable gland:
1
°
1
Polarity reversal protection. The voltage must not fall below 12 V.
< 0.001 Ncm with shaft dia. 2 mm
< 0.03 Ncm with shaft dia. 6 mm
resp. 1/4˝, without additional gear
Approx. 0.6 ... 3.2 Ncm with additio-
nal gear, depending on transmission
ratio
Programmable for sense of rotation
clockwise or counter-clockwise
H = 12 to 33 V DC
(possible with standard version,
non- Ex)
H = 12 to 30 V DC
(necessary with Ex version, type of
protection "Intrinsically safe"
EEx ia IIC T6)
< 0.3% p.p.
:
Load-independent DC current
A
4 to 20 mA, proportional to the input
angle
H [V] – 12V
R
max. [kΩ] =
ext
H
1
= DC power supply
I
= Output signal end value
A
Measuring range
Limit of error ≤ 0.5% with linear
characteristic
Acc. to EN 60 068-2-27
For specifi cation concerning the
static load on the shaft the manu-
facturer must be contacted
Any
Cast aluminium
Corrosion resistant fi nish
Plastic protection cap
Metal
IA [mA]