6. Specification and ordering information
Order Code
1. Mechanical design
Plug-in module for 19" rack-mounted case
2. Duties
I
0 0 (1 current measurement I1)
I
I
0 (2 current measurements I1 and I2)
I
I
I
(3 current measurements I1, I2
and I3)
U 0 0 (1 voltage measurement U1)
U U 0 (2 voltage measurements
U1 and U2)
U U U (3 voltage measurements
U1, U2 and U3)
U 0 I
(1 voltage measurements U1 and
1 current measurements I3)
I
I
U (2 current measurements I1, I2 and
1 voltage measurement U3)
U U I
(2 voltage measurements U1, U2
and 1 current measurement I3)
3. Nominal frequency
50 Hz
60 Hz
4. Measuring range I1 resp. U1 (meas. input)
0 ... 1 A
0 ... 1.2 A
0 ... 5 A
0 ... 6 A
Non-standard 0 ... 0.50 to 0 ... 10
0 ... 100/√3 V
0 ... 110/√3 V
0 ... 120/√3 V
0 ... 100 V
0 ... 110 V
0 ... 116.66 V
0 ... 120 V
0 ... 125 V
0 ... 133.33 V
0 ... 150 V
0 ... 250 V
0 ... 400 V
0 ... 500 V
Non-standard 0 ... 20.00 to 0 ... 660 ......[V]
5. Output signal 1 (measuring output)
≥ 200 kΩ/V
0 ... 10 V, R
ext
Non-standard
0 ... 0.060 to 0 ... < 10, R
≤ 15 kΩ
0 ... 1 mA, R
ext
≤ 3 kΩ
0 ... 5 mA, R
ext
≤ 1,5 kΩ
0 ... 10 mA, R
ext
≤ 750 Ω
0 ... 20 mA, R
ext
Non-standard 0...>1,00 to 0...<20
18
505 –
2
A
B
C
D
E
F
G
H
J
1
2
1
2
3
4
......[A]
9
A
B
C
D
E
F
G
H
J
K
L
M
N
Z
1
......[V]
9
≥ 200 kΩ/V
ext
A
B
C
D
......[mA]
Z
Order Code
6. Measuring range I2 resp. U2 (meas. input)
Not provided for measuring input I2 resp. U2
0 ... 1 A
0 ... 1.2 A
0 ... 5 A
0 ... 6 A
Non-standard
0 ... 0.50 to 0 ... 10
0 ... 100/√3 V
0 ... 110/√3 V
0 ... 120/√3 V
0 ... 100 V
0 ... 110 V
0 ... 116.66 V
0 ... 120 V
0 ... 125 V
0 ... 133.33 V
0 ... 150 V
0 ... 250 V
0 ... 400 V
0 ... 500 V
Non-standard
0 ... 20.00 to 0 ... 660
7. Output signal 2 (measuring output)
Not provided for output 2
≥ 200 kΩ/V
0 ... 10 V, R
ext
Non-standard
0 ... 0.060 to 0 ... < 10, R
≤ 15 kΩ
0 ... 1 mA, R
ext
≤ 3 kΩ
0 ... 5 mA, R
ext
≤ 1.5 kΩ
0 ... 10 mA, R
ext
≤ 750 Ω
0 ... 20 mA, R
ext
Non-standard
0 ... > 1.00 to 0 ... < 20
8. Measuring range I3 resp. U3
Not provided for measuring input I3 resp. U3
0 ... 1 A
0 ... 1.2 A
0 ... 5 A
0 ... 6 A
Non-standard
0 ... 0.50 to 0 ... 10
0 ... 100/√3 V
0 ... 110/√3 V
0 ... 120/√3 V
0 ... 100 V
0 ... 110 V
0 ... 116.66 V
0 ... 120 V
0 ... 125 V
0 ... 133.33 V
0 ... 150 V
0 ... 250 V
0 ... 400 V
0 ... 500 V
Non-standard
0 ... 20.00 to 0 ... 660
505 –
0
1
2
3
4
......[A]
9
A
B
C
D
E
F
G
H
J
K
L
M
N
......[V]
Z
0
1
......[V]
9
≥ 200 kΩ/V
ext
A
B
C
D
......[mA]
Z
0
1
2
3
4
......[A]
9
A
B
C
D
E
F
G
H
J
K
L
M
N
......[V]
Z