Output
Output signal
10
11
12 13
+
4-20mA
SINEAX F535
fS=50Hz; fG=49.5-50-50.5Hz
10-230V
U
G
1
2
3
4 5
U
G
Measuring inputs
Fig. 5. Declaration to type label.
Symbol
Meaning
Double insulation, device of protection class 2
Test voltage of insulation according to IEC60051:
3,7
AC 3.7 kV
Class icon to the EN60688:
0,5
error limit 0.5% of span
CE conformity mark. The device fulfi lls the require-
ments of the applicable EC directives.
CSA approved for USA and Canada
fi le-nr. 204767
Germanischer Lloyd
Type approval certifi cate: 12 261-98 HH
Caution!
General hazard point.
Read the operating instructions.
General symbol: Input
General symbol: Output
General symbol: Power supply
Measurement category CAT III for current and vol-
CAT III
tage inputs

6. Commissioning and maintenance

Switch on the power supply and the measuring inputs. It is
possible during the operation to disconnect the output line and
to connect a check instrument, e.g. for a functional test.
No maintenance is required.
Camille Bauer AG
0,5
3,7
Switzerland
Ord: 000/00F535/010/1
85-230V DC/AC
50/60Hz 3VA
U
S
+
6
7
8
9
U
S
Power supply

7. Releasing the transducer

Release the transducer from a top-hat rail as shown in
Fig. 6.
Fig. 6

8. Dimensional drawing

112.5
114.1
Fig. 7. Housing type P13/70 onto a top-hat rail (35 ×15 mm or
35×7.5 mm, acc. to EN 50 022).

9. Instruments admissions

Germanischer Lloyd
Type approval certifi cate: 12 261-98 HH
CSA approved for USA and Canada
fi le-nr. 204767
FCC Compliance and Canadian DOC Statement
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to both
part 15 of the FCC Rules and the radio interference regu-
lations of the Canadian Department of Communications:
These limits are designed to provide reasonable protec-
tion against harmful interference when the equipment is
operated in a commercial environment. This equipment
generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in
a residential area is like to cause harmful interference
in which case the user will be required to correct the
interference at his own expense.
10
11
12 13
1
2
3
4 5
6
7
8
9
70
11

Publicité