8 - ADVANCED PROGRAMMING MODE
8.5
PREVIOUS DAYS WATER USAGE (Pd):
Not viewed in timeclock regeneration mode.
Press the
water usage recorded. This display is used as an aid in the valve maintenance and is not an option setting.
The unit of measure used depends on the display format chosen
Ex.: 28,4 m
3
8.6
CHLORINE CELL ACTIVATION (J):
Press the
function during cycle 1.
Ex.: - No chlorinator installed
- Chlorinator to turn on during the cycle 1
8.7
CHLORINE CELL POWER DURATION
Press the
Chlorine cell power on duration.
Note: During a regeneration with the chlorine cell set, for example cycle 2, the regeneration display
will show:
8.8
REGENERATION DAY OVERRIDE (A)
In timeclock regeneration mode, a value must be set.
Press the
day override option setting. This override setting determines the maximum amount of time (in days) the
softener can be in service without a regeneration, regardless of the volume of water used or the lack of a
sensor signal. The regeneration begins at the set regeneration time.
Ex.: - Override every 7 days
- Option cancelled
8.9
VOLUME OVERRIDE (b)
Not viewed in timeclock regeneration mode.
Press the
maximum amount of water that can be used before a regeneration cycle is called for.
This option is typically used to bypass standard reserve or capacity calculations made by the electronics.
When this feature is used with meter delayed regeneration systems, it will be up to the installer to determine
a reserve capacity and subtract it from the calculated full capacity. The unit of measure depends on the
display format chosen(1).
Ex.: Override every 2.6 m
(1) The unit of measure depends on the display format chosen.
All examples above are based on the cubic meter format (see point 6.17)
29
6700 / 6765
button . This display is identified by the letters "Pd". This display shows the previous days
(1)
button. This display is identified by the letter "J". This display is used to activate the chlorine
button. This display is identified by the letter "dJ". This display is used to set
button.This parameter is identified by the letter "A". This option is used to set the regeneration
button . This display is identified by the letter "b". The volume override option is used to set the
3 (1)
.
(1)
6600 – 6665 – 6700 – 6765
E
N
G
L
I
S
H
[Pd - - 28.4]
[J- - - OFF]
[J- - - - - -1]
[2C - - 38.2]
[A - - - - - 7]
[A - - - OFF]
[b - - 2600]