MANUFACTURER
Pentair Manufacturing Italy Srl
Via Masaccio, 13
56010 Lugnano di Vicopisano (PI) – Italy
2.2
WARNINGS
The manufacturer will not be held liable for any damages to people or properties resulting from an improper use of
the device not compliant with the following instructions.
Whenever this guide doesn't clarify all doubts about installation, service or maintenance, please contact the technical
support of the company that has installed the device.
Device installation must be done by a qualified technician according to the current standards and regulations, using
tools compliant with a device safety use and referring to that technician also for device maintenance.
In case of out of order or malfunction, before performing any kind of action on the device, please ensure to have
disconnected the transformer from the power source, to shut off inlet water supply to the valve and to drain water
pressure opening a tap down-line of the valve.
2.3
INTENDED USE
The device is intended for residential, commercial or light industry environment (ref. EN 50081-1) use only and it is
purpose-built for treatment and softening of water coming from supply network.
2.4
TECHNICAL DATA
Transformer: 230Vac, 50/60Hz, 15VA, Class II.
Controller: 24Vac, 50/60Hz, 5W, Class III.
The device must only be used with the transformer provided in order to guarantee safety voltage supply.
2.5
WATER PRESSION
A minimum of 1,4 bar of water pressure is required for the regeneration valve to operate effectively. Do not exceed
8,5 bar; if you face this case, you should install a pressure regulator upstream the system.
2.6
ELECTRICAL CONNECTION
An uninterrupted current supply is required. Please make sure that your voltage supply is compatible with your unit
before installation. If the electrical cable is damaged, it must imperatively be replaced by a qualified personal.
2.7
ExISTING PLUMBING
Existing plumbing should be in a good shape and free from limescale. In doubt, it is preferable to replace it. The instal-
lation of a pre filter is always advised.
2.8
BY-PASS
Always provide a by pass valve for the installation, if the unit is not equipped with one.
2.9
WATER TEMPERATURES
Water temperature is not to exceed 43°C, and the unit cannot be subjected to freezing conditions.
2.10
DISINFECTION OF WATER CONDITIONERS
The materials of construction of the modern water conditioner will not support bacterial growth, nor will these
materials contaminate a water supply. In addition, during normal use, a conditioner may become fouled with organic
matter, or in some cases with bacteria from the water supply. This may result in an off-taste or odor in the water.
Thus, your conditioner may need to be disinfected after installation. Some conditioners will require periodic disinfec-
tion during their normal life. Consult your installing dealer for more information on disinfecting your conditioner.
2.11
ENVIRONMENTAL CONDITIONS
4
2 - GENERAL ADVICE
IT IS STRICTLY FORBIDDEN FOR NOT QUALIFIED PER-
SONAL, TO ACCEDE TO SYSTEM'S INTERNAL PARTS TO
PERFORM ANY KIND OF TECHNICAL ACTION.
• Indoor Use Only
• Altitude up to 2000m
• Temperature from 5°C to 40°C
• Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C
• Mains supply voltage fluctuations up to ±10% of the nominal voltage
6600 – 6665 – 6700 – 6765