Technical data
Power supply
Alternating voltage 230 V / 50 Hz, single phase
Range approx. 215 V - 245 V / 50 – 60 Hz.
Output current:
Charging current max. 12 A, arithmetic average, elec-
(Charging current)
tronically regulated according to the charging charac-
teristic curve IUoU.
Output voltage:
Direct voltage 12 V
Charging process:
Automatic
Automatic switching:
ON when battery voltage reached 13.5 V
(Main charging phase)
OFF when battery voltage reached 14.4 V
Automatic switching:
Six hours constant at 14.4 V
(Timer)
Automatic switching:
Holding charge, constant at 13.8 V.
(Holding charge phase)
Application:
Parallel operation, buffer operation, general charging
operation
Temperature:
Ambient temperature of -25° C to +35° C. During
operation, the housing may heat up to approx. 75° C.
Cooling:
By convection
Implementation:
According to Association of German Electrotechnical
Engineers regulations and the provisions of the In-
strument Safety Act.
Test labelling:
Use:
For charging batteries with a rated voltage of 12 V
and a capacity of 60 - 120 Ah.
Minimum voltage 1.5 V.
Housing:
Aluminium, painted blue/black, ventilated
Length/width/height:
235 mm / 150 mm / 105 mm
Weight:
4.7 kg (47 N)
!
" # $ %