Technical data
Power supply
Alternating voltage 230 V / 50 Hz, single-phase
Range 180 V – 250 V / 50 – 60 Hz
Output current
Charging current max. 16 A, arithmetic average, electronically
regulated according to the charging characteristic curve IUoU.
Output voltage
Direct voltage 12 V
Charging process
Automatic
Automatic switching (Bulk phase)
OFF when battery voltage reached 14.4 V,
charging current < 14.5 A.
Automatic switching (Absorption phase)
Ten hours at a constant 14.4 V for gel or AGM batteries.
Four hours at a constant 14.4 V for liquid electrolyte batteries.
Automatic switching (Float phase)
Float phase, constant at 13.8 V
Temperature dependent control
The values of the automatic switching refer to a battery tem-
perature of 20 °C. If a temperature sensor is used with the
battery, these values will vary in accordance with the battery
temperature.
High temperature –> Lowering of the threshold values.
Low temperature –> Higher threshold values.
Application
Parallel operation, buffer operation, general charging operation
Temperature
Ambient temperature of -25 °C to +35 °C.
During operation, the housing may heat up to approx. 75 °C.
Cooling
By convection
Implementation
According to Association of German Electrotechnical Engineers
regulations and the provisions of the Instrument Safety Act.
Test labelling
The right to make technical modifications is reserved.
Use
For charging batteries with a rated voltage of 12 volt and a
capacity of 50 – 160 Ah.
19