Important
Make sure that the ventilation slots remain unobstructed! The minimum clear
distance must be 100 mm all around! Insufficient ventilation can cause over-
heating of the device! The device is designed for operation in ambient tempera-
tures of up to 25° C. If inadequate air circulation or excessive surrounding
temperature causes the temperature inside the device to rise, the integrated
thermal switch will turn the device off. It will switch itself back on automati-
cally when it has cooled down.
Assembling the flat sleeves
Prepare the connecting cable. Ensure that the flat sleeves for the correct cable
cross-section are pressed firmly onto the cable ends, and are securely attached!
Loose contacts may lead to short circuiting and to poor connection. Cable ends
designed for use with cable end sleeves must not be soldered.
Remove a length of 5 mm of insulation from the connecting cable.
# $%
Push the flat sleeve over the connecting cable, so that the bared part sits in the
front clamp. The second clamp must enclose the insulated part.
# $%
Now attach the connecting cable to the flat sleeve by pressing the clamps to-
gether, using suitable crimping pliers.
# $% !
Check that the connecting cable is firmly attached to the flat sleeve.
Push a piece of shrink-on hose over the flat sleeve. The hose must completely
cover the flat sleeve. Use an air heater or hair dryer to heat the shrink-on hose
until it pulls together and firmly encloses the flat sleeve.