Technical data
Power supply:
Alternating voltage 230 V / 50 Hz, single phase
Range approx. 215 V - 245 V
Output current:
Charging current max. 12 A, arithmetic average,
(Charging current)
electronically regulated according to the charging
characteristic curve IUoU
Output voltage:
Direct voltage 12 V
Charging process:
Automatic
Automatic
ON when battery voltage reached 13.5 V
switching:
OFF when battery voltage reached 14.4 V
(Main
charging process)
Automatic
Six hours constant at 14.4 V
switching:
(Timer)
Automatic
Holding charge, constant at 13.8 V
switching:
(Holding
charge)
Application:
Parallel operation, buffer operation, general charging
operation
Temperature:
Ambient temperature of -25° C to +25° C.
During operation, the housing may heat up to approx. 70°
C.
Cooling:
By convection
Implementation:
According to Association of German Electrotechnical
Engineers regulations and the provisions of the
Instrument Safety Act.
Test labelling:
Use:
For charging batteries with a rated voltage of 12 V and a
capacity of 60 -120 Ah
Minimum voltage 1.5 V
Housing:
Aluminium, painted red/black, ventilated
Length: 235 mm
Width: 150 mm
Weight:
4,5 kg (45 N)
18
Lerchenfeldstr. 9 87600 Kaufbeuren Tel.: +49 (0)8341 9764-0 Fax: +49 (0)8341 67806
"#$ % &'(
Height: 105 mm