Inappropriate use

-
*
The charger must not be used to charge 6 volt lead batteries. If batteries with a
rated voltage of 6 volt are charged with the charger, gas is created immediately.
Explosive oxyhydrogen gas is generated.
The charger must not be used to charge non-rechargeable batteries and/or
nickel-cadmium batteries.
When charging these battery types with the charger, the outer cover may rup-
ture explosively.

Description

The charger employs the latest charging technology. This technology permits
high output together with low weight and small dimensions. The high quality
electronics it incorporates allow it to operate with almost no dissipation of
waste power. Automatic charging affords protection and prevents harmful
battery overload. This considerably extends the life of the battery.
The charger starts to operate as soon as it is connected to the mains. The green
function display lights up when:
Mains power is on.
The battery is correctly connected.
The charger is designed for parallel operation and buffer operation. At all
times, consumers can remain connected, be added or switched off. Consumers
are supplied with the power and the battery is charged at the same time. Con-
sumer current should be lower than the maximum charging current, otherwise
the battery will not be charged.
The charger incorporates a thermal switch to protect it from overheating. If the
device becomes too hot in operation, the thermal switch will turn it off. It will
switch itself back on automatically when it has cooled down.