Technical data
Power supply
Alternating voltage 230 V / 50 Hz, single-phase
Range 195 V - 264 V / 50 – 60 Hz.
Output current:
Charging current max. 60 A, arithmetic average,
(Charging current for
electronically regulated according to the charging
battery II)
characteristic curve IUoU.
Output current:
When the battery potential of battery II reaches 14.3 V, a
(Charging current for
parallel connection is established with battery I.
battery I)
Compensating current dependent on the charge state of
battery I (starter battery). If the voltage of the battery II
drops below 13.2 V, the parallel circuit is automatically
disconnected.
Output voltage:
Direct voltage 12 V
Charging process:
Automatic
Automatic
OFF when battery voltage reached 14.4 V, charging
switching:
current < 54 A.
(Main charging
process)
Automatic
Ten hours constant 14.4 V in the case of gel batteries.
switching:
Four hours constant 14.4 V in the case of liquid batteries.
(Post charging phase)
Automatic
Holding charge, constant at 13.8 V.
switching:
(Holding charge)
Temperature
The values of the automatic switching refer to a battery
dependent control
temperature of 20° C. When using a temperature sensor at
(optional)
the battery II, these values vary as a function of the
battery temperature.
High temperature => Lowering of the threshold values.
Low temperature => higher threshold values.
Application:
Parallel operation, buffer operation, general charging
operation
Temperature:
Ambient temperature of –25 °C to +35 °C. During
operation, the housing may heat up to approx. 75 °C.