WallPerfect W 995
Put together the spray head (fig. 15, 1)
and air pipe (2).
Insert the pull wire (3) into the guide rail
(4) on the bottom side of the air pipe
and pull it over the guide hook (5) to the
spray head.
Push back the trigger (6) and connect
the pull wire. Set the pull wire at a
tension using the adjustment screw (7).
Attention! Do not tighten
the adjustment screw (7) too
much. The nozzle opening has
to remain closed at this point,
as otherwise material might
leak out.
Push the end of the material hose (8)
into the slot (9) on the spray head.
Clip the cover (10) back on to the spray
head.